Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: B & B POLE BUILDINGS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of B & B POLE BUILDINGS in 422 S. 24TH ST, CAMP HILL, PA 17011 (NAICS 238160). OSHA activity number 344447214.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B & B Pole Buildings — free Get an email when a new federal OSHA severe-injury report for B & B Pole Buildings is published. One employer, no account, unsubscribe in one click.
Site address
422 S. 24TH ST
City
CAMP HILL
State
PA
ZIP
17011
Mailing
602 W HIGH ST, HUMMELSTOWN, PA 17036
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

1 citation on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 5, 2019
Abate by
Jan 3, 2020
Penalty
Initial $3,978 · Current $2,984 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.      Camp Hill Public Works Department - Compost Facility: Employees were observed installing standing seam metal roofing on a 4/12 sloped roof with ground to eave heights as great as 18 feet above ground. Employees were not protected from falling on or about November 14, 2019.     Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $2984
  • — Z (S) $3978

View B & B Pole Buildings's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344447214.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.