LEWISBURG, WV —
OSHA Inspection: GREENBRIER VAULT COMPANY, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GREENBRIER VAULT COMPANY, LLC in 202 RAMBLER ROAD, LEWISBURG, WV 24901 (NAICS 327390). OSHA activity number 344449533.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREENBRIER VAULT COMPANY, LLC
- Site address
- 202 RAMBLER ROAD
- City
- LEWISBURG
- State
- WV
- ZIP
- 24901
- Mailing
- P.O. BOX 188, RONCEVERTE, WV 24970
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Dec 18, 2019
- Abate by
- Jan 23, 2020
- Penalty
- Initial $2,842 · Current $1,421 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Shop Area: On November 13, 2019 and times prior, employees conduct servicing and maintenance on equipment such as but not limited to, concrete mixer and concrete auger. The employer has not established an energy control program which consists of energy control procedures, employee training and periodic inspections.
Recent events (2)
- — I (S) $1421
- — Z (S) $2842
1910.147 E01
- Issued
- Dec 18, 2019
- Abate by
- Jan 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(e)(1): The work area was not inspected to ensure that nonessential items have been removed and to ensure that machine or equipment components are operationally intact: (a) Concrete Auger: On November 6, 2019, the employer did not ensure that the machine guarding for the auger chain drive was re-installed following maintenance and servicing of the chain drive.