Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE L.E. MYERS CO.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of THE L.E. MYERS CO. in 831 N FEDRAL HWY, HALLANDALE, FL 33009 (NAICS 237130). OSHA activity number 344456470.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The L.E. Myers CO. — free Get an email when a new federal OSHA severe-injury report for The L.E. Myers CO. is published. One employer, no account, unsubscribe in one click.
Establishment
THE L.E. MYERS CO.
Site address
831 N FEDRAL HWY
City
HALLANDALE
State
FL
ZIP
33009
Mailing
24925 STATE RD 46, SORRENTO, FL 32776
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
982
Ownership type
A

4 citations on file for this inspection.

1926.950 B02 III

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 12, 2020
Abate by
May 22, 2020
Penalty
Initial $13,494 · Current $0 Reduced
29 CFR 1926.950(b)(2)(iii): Each qualified employee was not trained and competent in the minimum approach distances specified in this subpart corresponding to the voltages to which the qualified employee will be exposed and the skills and techniques necessary to maintain those distances:  On or about November 15, 2019, at jobsite location 831 N. Federal Highway, Hallandale, Florida, employees were exposed to an electrocution hazard while working near 7,620-volt phase to ground power lines without the employer ensuring that employees were trained to recognize the hazards associated with keeping the minimum approach distance from energized power lines.
Recent events (3)
  • — J (S) $0
  • — C (S) $13494
  • — Z (S) $13494

1926.960 C01 III

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 12, 2020
Abate by
May 22, 2020
Penalty
Initial $13,494 · Current $0 Reduced
29 CFR 1926.960(c)(1)(iii): The employer did not ensure that no employee approached or took any conductive object closer to exposed energized parts than the employer's established minimum approach distance:  On or about November 15, 2019, at jobsite location 831 N. Federal Highway, Hallandale, Florida, an employee carried an energized mechanical jumper inside a truck-mounted bucket, exposing the employee to an electrocution hazards.
Recent events (3)
  • — J (S) $0
  • — C (S) $13494
  • — Z (S) $13494

1926.960 C02 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 12, 2020
Abate by
May 22, 2020
Penalty
Initial $13,494 · Current $0 Reduced
29 CFR 1926.960(c)(2)(i): When and employee used rubber insulating gloves as insulation from energized parts, the employer did not ensure that rubber insulating sleeves were also used:  On or about November 15, 2019, at jobsite location 831 N. Federal Highway, Hallandale, Florida, an employee was exposed to an electrical shock and/or electrocution hazard when using rubber-insulating gloves as insulation from energized parts without using rubber-insulating sleeves.
Recent events (3)
  • — J (S) $0
  • — C (S) $13494
  • — Z (S) $13494

1926.960 G01

Deleted Other-than-serious 1 instance 3 exposed
Issued
May 12, 2020
Abate by
May 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.960(g)(1): The employer did not assess the workplace to identify employees exposed to hazards from flames or from electric arcs:  On or about November 15, 2019, at jobsite location 831 N. Federal Highway, Hallandale, Florida, employees worked near high voltage live wires, without the employer assessing the workplace prior to commencing to identify possible arc flames.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

View The L.E. Myers CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344456470.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.