Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLMINN-X, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of COLMINN-X, INC. in 300 W 53RD PL UNIT L2, DENVER, CO 80216 (NAICS 332999). OSHA activity number 344458062.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Colminn-X, INC. — free Get an email when a new federal OSHA severe-injury report for Colminn-X, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
COLMINN-X, INC.
Site address
300 W 53RD PL UNIT L2
City
DENVER
State
CO
ZIP
80216
Mailing
300 W 53RD PL UNIT L2, DENVER, CO 80216
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
5
Ownership type
A

5 citations on file for this inspection.

1910.1200 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 13, 2020
Abate by
Mar 2, 2020
Penalty
Initial $1,705 · Current $1,705
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   (a) Colminn-X, Inc. at 300 W. 53rd Ave. Denver, CO 80216: On or before 11/19/19 the employer did not develop or implement a written hazard communication program in accordance with this standard. This condition exposed employees to chemical hazards including but not limited to: -welding fumes -chromium (3) -chromium (6) -brake cleaner -enamel paint -acetone -anti splatter spray
Recent events (1)
  • — Z (S) $1705

1910.1200 H01

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 13, 2020
Abate by
Mar 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) Colminn-X, Inc. at 300 W. 53rd Ave. Denver, CO 80216: On or before 11/19/19 the employer did not provide effective information and training to employees regarding the chemical hazards in the workplace. This condition exposed employees to chemical hazards including but not limited to: -welding fumes -chromium (3) -chromium (6) -brake cleaner -enamel paint -acetone -anti splatter spray
Recent events (1)
  • — Z (S) $0

1910.1026 L01 I

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 13, 2020
Abate by
Mar 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(l)(1)(i): 29 CFR 1910.1026(l)(1): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to chromium (VI) were provided with information and training as required by the Hazard Communication standard, 29 CFR 1910.1200:   (a) Colminn-X, Inc. at 300 W. 53rd Ave. Denver, CO 80216: On or before 11/19/19 the employer did not provide effective information and training to employees regarding the hazards associated with inhalation of chromium (VI) in accordance with this standard. This condition exposed employees to chromium (VI).
Recent events (1)
  • — Z (S) $0

1910.178 A04

Other-than-serious 1 instance 5 exposed
Issued
Jan 13, 2020
Abate by
Mar 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:   (a) Colminn-X, Inc. at 300 W. 53rd Ave. Denver, CO 80216: On or before 11/19/19 the employer did not ensure that modifications or additions that effect the capacity of the Daewoo sit down forklift [model G25P3, serial# D202929] were approved by the manufacturer. Home made fork extensions were used without first obtaining written permission by the forklift manufacturer in accordance with this standard. This condition exposed employees to struck by hazards.
Recent events (1)
  • — Z (O) $0

1910.178 A06

Other-than-serious 1 instance 5 exposed
Issued
Jan 13, 2020
Abate by
Mar 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition:  (a) Colminn-X, Inc. at 300 W. 53rd Ave. Denver, CO 80216: On or before 11/19/19 the employer did not ensure that all nameplates and markings were maintained in a legible condition in that the data plate affixed to the Daewoo sit down forklift [model G25P3, serial# D202929] was not legible.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344458062.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.