GROVE CITY, OH —
OSHA Inspection: WILLIAMS-SONOMA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WILLIAMS-SONOMA, INC. in 3420 URBANCREST INDUSTRIAL DRIVE, GROVE CITY, OH 43123 (NAICS 493190). OSHA activity number 344460852.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WILLIAMS-SONOMA, INC.
- Site address
- 3420 URBANCREST INDUSTRIAL DRIVE
- City
- GROVE CITY
- State
- OH
- ZIP
- 43123
- Mailing
- 3420 URBANCREST INDUSTRIAL DRIVE, GROVE CITY, OH 43123
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493190
- Employees
- 87
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A01
- Issued
- Dec 10, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $10,419 · Current $10,419
General-duty citation text
29 CFR 1910.22(a)(1): (1) All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. a. On and/or before November 20, 2019, in the recycling area, passageways and walking-working surfaces were not kept in a clean and orderly condition due to cardboard boxes, Styrofoam type material, trash, and/or other items which were stored/staged in the area enclosing the baler operation and obstructing entry and exit into and out of the area.
Recent events (2)
- — I (S) $10419
- — Z (S) $10419
1910.37 A03
- Issued
- Dec 10, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $52,096 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. a. On and/or before November 20, 2019, in the recycling area, exit routes were not free and unobstructed due to cardboard boxes, Styrofoam type material, trash, and/or other items which were stored/staged in the area enclosing the baler operation and obstructing entry and exit into and out of the area. Williams Sonoma was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.37(a)(3), which was contained in OSHA inspection number 1018232, citation number 1, item number 1b and was affirmed as a final order on February 26, 2015, with respect to a workplace located at 3301 Veterans Memorial Boulevard, Suite 54 A, Metairie, LA 70002. Williams-Sonoma Stores, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.37(a)(3), which was contained in OSHA inspection number 1188559, citation number 1, item number 1 and was affirmed as a final order on January 17, 2017, with respect to a workplace located at 4047 Westheimer Road, Houston, TX 77027.
Recent events (2)
- — I (S) $0
- — Z (R) $52096
1910.212 A01
- Issued
- Dec 10, 2019
- Abate by
- Dec 30, 2019
- Penalty
- Initial $10,419 · Current $10,419
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. a. On and/or before November 20, 2019, in the recycling area, the Harris/Selco Baler (model: HL-50; S/N: 020170425) was not guarded on the control panel side where an access cover was removed due to damage, thereby exposing employees to struck-by and/or caught-in hazards from moving parts.
Recent events (2)
- — I (S) $10419
- — Z (S) $10419
1910.305 B02 I
- Issued
- Dec 10, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $10,419 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. a. On and/or before November 20, 2019, in the recycling area, the metal junction box containing electrical conductors for the dock light at door 21 did not have a cover.
Recent events (2)
- — I (O) $0
- — Z (S) $10419
1910.303 G01
- Issued
- Dec 10, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. a. On and/or before November 20, 2019, in the recycling area, access and working space around the electrical panels/cabinets was obstructed due to cardboard boxes, Styrofoam type material, trash cans, a pallet, fan, chair, and/or other items which were stored/staged in the area. Williams-Sonoma Stores, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.303(g)(1), which was contained in OSHA inspection number 1188559, citation number 1, item number 2 and was affirmed as a final order on January 17, 2017, with respect to a workplace located at 4047 Westheimer Road, Houston, TX 77027. Williams-Sonoma Stores, Inc. Store #517 was previously cited for an equivalent violation of this occupational safety and health standard 29 CFR 1910.303(g)(1)(ii), which was contained in OSHA inspection number 1281710, citation number 1, item number 3 and was affirmed as a final order on January 10, 2018, with respect to a workplace located at 5145 Peachtree Parkway, Suite #405, Norcross, GA 30092.
Recent events (2)
- — I (O) $0
- — Z (R) $0
1910.305 G01 IV A
- Issued
- Dec 10, 2019
- Abate by
- Dec 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: 29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure. a. On and/or before November 20, 2019, in the recycling area, the Fostoria Industries dock light at door 21 was hardwired into a metal junction box. b. On and/or before November 20, 2019, in the recycling area, the Fostoria Industries dock light at door 19 was hardwired into a metal junction box.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Williams-Sonoma, INC.
View Williams-Sonoma, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 493190)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344460852.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.