OSHA Inspection: CNH INDUSTRIAL AMERICA, LLC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CNH INDUSTRIAL AMERICA, LLC. in 3301 S. HOOVER RD., WICHITA, KS 67215 (NAICS 333120). OSHA activity number 344461777.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CNH Industrial America, LLC. — free Get an email when a new federal OSHA severe-injury report for CNH Industrial America, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
3301 S. HOOVER RD.
City
WICHITA
State
KS
ZIP
67215
Mailing
3301 S. HOOVER RD., WICHITA, KS 67215
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333120
Employees
490
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 13 exposed
Issued
Mar 23, 2020
Abate by
Jun 15, 2020
Penalty
Initial $13,494 · Current $13,494
OSH ACT of 1970 SECTION (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing, pinning, and struck-by hazards:  The employer is failing to protect employees from amputation, crushing, pinning, and struck-by hazards.  This was most recently documented on or about November 20, 2019 at CNH Industrial, LLC. located at 3301 S. Hoover Road Wichita, Kansas. The employer exposed employees to amputation, crushing, pinning, and struck-by hazards while operating the Funac Robotic Arm, Model: M-2000iA 900L in the 260 OP welding workstation, which was improperly safeguarded.  Among other methods, one feasible and acceptable means to correct this hazard includes but is not limited to the following:    1)  Comply with the FANUC Robot M-2000iA MECHANICAL UNIT OPERATOR'S MANUAL MAROCM20003091E REV. G supplied by the manufacturer to perform a risk assessment to determine what safeguarding is best for the process to protect the employees.  2)  Install safeguarding devices in accordance with Clause 10 of ANSI/RIA R16.06-1999 (Robots and Robot Systems - Safety Requirement).   3)  Install a local alarm fault reset that can only be initiated at that workstation by the operator who knows what is going on at that time in accordance with ANSI B11.19 - 2010 American National Standard for Machines - Performance Criteria for Safeguarding, Section 6.5.4 "Reset of the perimeter safeguarding shall only be performed after the hazard zone is clear of all individuals".
Recent events (2)
  • — I (S) $13494
  • — Z (S) $13494

1910.212 A01

Deleted Serious Gravity 5 2 instances 1 exposed
Issued
Mar 23, 2020
Abate by
Apr 16, 2020
Penalty
Initial $9,639 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  The employer is failing to protect employees from amputation, and struck-by hazards. This was most recently documented on or about November 25, 2019 at CNH Industrial, LLC. located at 3301 S. Hoover Rd. Wichita, Kansas. The employer failed to adequately guard drill presses. Employees engaged in fabrication activities in the Experimental Fabrication and Tooling Shop were exposed to amputation and struck-by hazards in that machine guarding was not provided for the following drill presses to ensure employees' protection from flying chips and debris.  1) Ikeda Radial Arm Drill Press, Model #RM-1175, Serial #81509, and 2) Powermatic Drill Press, Model #1200, Serial #920V675.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9639

1910.215 B09

Other-than-serious 1 instance 1 exposed
Issued
Mar 23, 2020
Abate by
Apr 16, 2020
Penalty
Initial $5,783 · Current $5,783
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    The employer is failing to protect employees from struck-by hazards. This was most recently documented on or about November 25, 2019 at CNH Industrial, LLC. located at 3301 S. Hoover Rd. Wichita, Kansas. The employer failed to ensure that the distance between the abrasive wheel periphery and the adjustable tongue guard was adjusted to no greater than one fourth inch. Employees engaged in grinding activities at the Wissota bench grinder located in the Experimental Fabrication and Tooling Shop were exposed to struck-by hazards in that the distance from the abrasive wheel to the adjustable tongue guard measured approximately 3/4 inches on the right wheel and 7/8 inches on the left wheel.     29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • — I (O) $5783
  • — Z (S) $5783

1910.303 B01

Other-than-serious 1 instance 1 exposed
Issued
Mar 23, 2020
Penalty
Initial $4,916 · Current $4,916
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    The employer is failing to protect employees from electrical shock hazards. This was most recently documented on or about November 25, 2019 at CNH Industrial, LLC. located at 3301 S. Hoover Rd. Wichita, Kansas. The employer failed to ensure that electrical equipment was free from recognized hazards. Employees engaged in production and maintenance activities at the Unit 1 and 2 Wire Harness Parts area by Section L-17 in the assembly shop were exposed to electrical shock hazards in that the 480V Square-D On/Off safety switch handle was broken.    29 CFR 1903.19(c)(2) abatement of the above violation was verified at time of inspection, no certification is required.
Recent events (2)
  • — I (O) $4916
  • — Z (S) $4916

View CNH Industrial America, LLC.'s full OSHA safety record →