MOUNT CARMEL, PA —
OSHA Inspection: REGENCY PLUS, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of REGENCY PLUS, INC in 2000 LOCUST GAP HIGHWAY, MOUNT CARMEL, PA 17851 (NAICS 326199). OSHA activity number 344462528.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REGENCY PLUS, INC
- Site address
- 2000 LOCUST GAP HIGHWAY
- City
- MOUNT CARMEL
- State
- PA
- ZIP
- 17851
- Mailing
- 2000 LOCUST GAP HIGHWAY, MOUNT CARMEL, PA 17851
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 59
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Feb 26, 2020
- Abate by
- Apr 13, 2020
- Penalty
- Initial $4,048 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Production Area: Employees were exposed to the unguarded unused portion of the blade while operating a Jet horizontal band saw, on or about November 21, 2019. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $4048
1910.147 C06 I
- Issued
- Feb 26, 2020
- Abate by
- Apr 13, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Mt. Carmel, PA: A periodic inspection of the lockout procedure was not conducted within the last 12 months to ensure that the procedure and the requirements of this standard are being followed, on or about November 21, 2019. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Regency Plus, INC
View Regency Plus, INC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344462528.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.