OSHA Inspection: REGENCY PLUS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of REGENCY PLUS, INC in 2000 LOCUST GAP HIGHWAY, MOUNT CARMEL, PA 17851 (NAICS 326199). OSHA activity number 344462528.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Regency Plus, INC — free Get an email when a new federal OSHA severe-injury report for Regency Plus, INC is published. One employer, no account, unsubscribe in one click.
Establishment
REGENCY PLUS, INC
Site address
2000 LOCUST GAP HIGHWAY
City
MOUNT CARMEL
State
PA
ZIP
17851
Mailing
2000 LOCUST GAP HIGHWAY, MOUNT CARMEL, PA 17851
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
59
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 26, 2020
Abate by
Apr 13, 2020
Penalty
Initial $4,048 · Current $2,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) Production Area: Employees were exposed to the unguarded unused portion of the blade while operating a Jet horizontal band saw, on or about November 21, 2019.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4048

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Feb 26, 2020
Abate by
Apr 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Mt. Carmel, PA: A periodic inspection of the lockout procedure was not conducted within the last 12 months to ensure that the procedure and the requirements of this standard are being followed, on or about November 21, 2019.  ABATEMENT CERTIFICATION REQUIRED