Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HENKEL US OPERATIONS CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HENKEL US OPERATIONS CORPORATION in 18371 CRANWOOD PKWY, WARRENSVILLE HEIGHTS, OH 44128 (NAICS 325520). OSHA activity number 344462619.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Henkel US Operations Corporation — free Get an email when a new federal OSHA severe-injury report for Henkel US Operations Corporation is published. One employer, no account, unsubscribe in one click.
Site address
18371 CRANWOOD PKWY
City
WARRENSVILLE HEIGHTS
State
OH
ZIP
44128
Mailing
18371 CRANWOOD PKWY., WARRENSVILLE HEIGHTS, OH 44128
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325520
Employees
53000
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Other-than-serious 1 instance 3 exposed
Issued
Jan 6, 2020
Penalty
Initial $13,260 · Current $9,282 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to the following:     On or about November 20, 2019, the employer did not ensure the Drum Pump-Drum Change Instruction and the Molteni #3 Mixer energy control procedures clearly and specifically outlined the techniques to be utilized for the control of hazardous energy.
Recent events (2)
  • — I (O) $9282
  • — Z (S) $13260

1910.147 D

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jan 6, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   On or about November 20, 2019, the employer did not ensure the established procedure for the application of energy control (lockout/tagout) covered the following elements and actions and was done in sequence during the removal of the drum pump from the Molteni #3 mixer.  Employees did not prepare for the drum pump removal or have knowledge of the type and magnitude of the gravity energy source, [per the 1910.147(d)(1) requirements], Isolating all energy sources [(d)(3)], affixing a lockout device to each energy isolating device [(d)(4)], control the stored energy [(d)(5)], and verify the equipment energy was isolated and de-energized prior to starting work [(d)(6)].  The established procedure did not cover verifying the equipment energy was isolated properly prior to starting work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Henkel US Operations Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344462619.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.