WARRENSVILLE HEIGHTS, OH —
OSHA Inspection: HENKEL US OPERATIONS CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HENKEL US OPERATIONS CORPORATION in 18371 CRANWOOD PKWY, WARRENSVILLE HEIGHTS, OH 44128 (NAICS 325520). OSHA activity number 344462619.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HENKEL US OPERATIONS CORPORATION
- Site address
- 18371 CRANWOOD PKWY
- City
- WARRENSVILLE HEIGHTS
- State
- OH
- ZIP
- 44128
- Mailing
- 18371 CRANWOOD PKWY., WARRENSVILLE HEIGHTS, OH 44128
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325520
- Employees
- 53000
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jan 6, 2020
- Penalty
- Initial $13,260 · Current $9,282 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to the following: On or about November 20, 2019, the employer did not ensure the Drum Pump-Drum Change Instruction and the Molteni #3 Mixer energy control procedures clearly and specifically outlined the techniques to be utilized for the control of hazardous energy.
Recent events (2)
- — I (O) $9282
- — Z (S) $13260
1910.147 D
- Issued
- Jan 6, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about November 20, 2019, the employer did not ensure the established procedure for the application of energy control (lockout/tagout) covered the following elements and actions and was done in sequence during the removal of the drum pump from the Molteni #3 mixer. Employees did not prepare for the drum pump removal or have knowledge of the type and magnitude of the gravity energy source, [per the 1910.147(d)(1) requirements], Isolating all energy sources [(d)(3)], affixing a lockout device to each energy isolating device [(d)(4)], control the stored energy [(d)(5)], and verify the equipment energy was isolated and de-energized prior to starting work [(d)(6)]. The established procedure did not cover verifying the equipment energy was isolated properly prior to starting work.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Henkel US Operations Corporation
View Henkel US Operations Corporation's full OSHA safety record →
More inspections in this industry (NAICS 325520)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344462619.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.