GORDONVILLE, PA —
OSHA Inspection: AMERIGAS PROPANE L.P.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERIGAS PROPANE L.P. in 3927 E. NEWPORT ROAD, GORDONVILLE, PA 17529 (NAICS 454310). OSHA activity number 344467055.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERIGAS PROPANE L.P.
- Site address
- 3927 E. NEWPORT ROAD
- City
- GORDONVILLE
- State
- PA
- ZIP
- 17529
- Mailing
- 3927 E. NEWPORT ROAD ATTN: PAUL MOORE, GORDONVILLE, PA 17529
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 454310
- Employees
- 24
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.101 B
- Issued
- Jan 29, 2020
- Penalty
- Initial $7,210 · Current $0 Reduced
General-duty citation text
29 CFR 1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6. Section 3.3.1 of the CGA Pamphlet P-1-1965 refers to storing cylinders in accordance with CGA and NFPA standards. The CGA Pamphlet P-1-2015 Section 5.8.4 states that "All compressed gas cylinders in service or in storage at user locations shall be secured to prevent from falling or rolling." a) Shop - On or about November 21, 2019, three (3) compressed gas cylinders of nitrogen were observed free standing and were not secured by any device to prevent the cylinders from falling, rolling, or getting knocked over. No abatement certification or documentation required.
Recent events (3)
- — F (S) $0
- — C (S) $7210
- — Z (S) $7210
1910.178 A04
- Issued
- Jan 29, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $7,210 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a) Yard - On or about November 21, 2019 and times prior thereto, employees operated a Hyster forklift (Model S50XM) with a fabricated metal basket supported by the forks and the employer did not obtain the manufacturers prior written approval. b) Yard - On or about November 21, 2019 and times prior thereto, employees operated a Hyster forklift (Model S50XM) with a Vestil lift boom forklift attachment supported by the forks and the employer did not obtain the manufacturers prior written approval. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — D (S) $0
- — C (S) $7210
- — Z (S) $7210
1910.178 A05
- Issued
- Jan 29, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $0 · Current $1,500
General-duty citation text
29 CFR 1910.178(a)(5): The user did not request, for trucks equipped with front-end attachments other than factory installed attachments, that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a) Yard - On or about November 21, 2019 and times prior thereto, employees operated a Hyster forklift (Model S50XM) with a fabricated metal basket supported by the forks and the truck was not marked to identify the attachment and approximate weight of the truck and basket combination as required. b) Yard - On or about November 21, 2019 and times prior thereto, employees operated a Hyster forklift (Model S50XM) with a Vestil lift boom forklift attachment supported by the forks and the truck was not marked to identify the attachment and approximate weight of the truck and basket combination as required. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $1500
- — C (S) $0
- — Z (S) $0
1910.178 L02 II
- Issued
- Jan 29, 2020
- Abate by
- Mar 17, 2020
- Penalty
- Initial $7,210 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a) Yard - On or about November 21, 2019 and times prior thereto, employees operated a Hyster forklift (Model S50XM) and the employer had not conducted the practical training and the workplace evaluation of employees as required under this standard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $7210
- — Z (S) $7210
1910.215 A04
- Issued
- Jan 29, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $7,210 · Current $0 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) Shop - The distance between the work rest and the grinding wheel measured approximately one and a half (1-1/2) inches on a Jet Electric bench grinder, on or about November 21, 2019. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $7210
- — Z (S) $7210
1910.215 B09
- Issued
- Jan 29, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch: a) Shop - There was no tongue guard installed on a Jet Electric bench grinder, on or about November 21, 2019. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Jan 29, 2020
- Penalty
- Initial $5,407 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Driver's Lounge - A 240v energized service panel was blocked with a permanently installed coat rack and wood shelving, on or about November 21, 2019. b) Shop - A 240v energized service panel was blocked with maintenance equipment and a metal storage rack, on or about November 21, 2019. No abatement certification or documentation required.
Recent events (3)
- — F (S) $0
- — C (S) $5407
- — Z (S) $5407
1910.178 M05 III
- Issued
- Jan 29, 2020
- Penalty
- Initial $0 · Current $1,500
General-duty citation text
29 CFR 1910.178(m)(5)(iii): Powered industrial truck(s), with the operator dismounted and within 25 feet of the truck still in his view, did not have the load engaging means fully lowered, controls neutralized, and the brakes set to prevent movement: a) Loading Dock - The load engaging means on a Hyster forklift (Model S50XM) were not fully lowered while the operator was working on the loading dock, on or about November 21, 2019. No abatement certification or documentation required.
Recent events (3)
- — F (O) $1500
- — C (O) $0
- — Z (O) $0
More inspections at Amerigas Propane L.P.
View Amerigas Propane L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 454310)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344467055.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.