Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE INDIUM CORPORATION OF AMERICA

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of THE INDIUM CORPORATION OF AMERICA in 111 BUSINESS PARK DRIVE, UTICA, NY 13502 (NAICS 331491). OSHA activity number 344469499.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Indium Corporation of America — free Get an email when a new federal OSHA severe-injury report for The Indium Corporation of America is published. One employer, no account, unsubscribe in one click.
Site address
111 BUSINESS PARK DRIVE
City
UTICA
State
NY
ZIP
13502
Mailing
111 BUSINESS PARK DRIVE, UTICA, NY 13502
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331491
Employees
300
Ownership type
A

3 citations on file for this inspection.

1910.217 C01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 30, 2020
Penalty
Initial $8,193 · Current $6,145 Reduced
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):  a)  Indium Cell Area, on or about 11/26/20: Bench Master Punch Press PNCH019 point of operation was not adequately guarded, the opening at the front measured 2.5-inches x 12-inches.
Recent events (2)
  • — I (S) $6144.75
  • — Z (S) $8193

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 30, 2020
Penalty
Initial $4,178 · Current $3,134 Reduced
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) S3 Nanofoil Area, on or about 11/22/19: A flexible cord with a quad metal receptacle box attached was used to provide power to a Shop Vacuum . The metal box is listed for permanent mounting only.
Recent events (2)
  • — I (S) $3133.5
  • — Z (S) $4178

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 30, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):  Flexible cords and cables were used as a substitute for the fixed wiring of a structure:      a) Extrusion Area, on or about 11/22/19: Racine 50 Ton No. 1, Rotary Pan Take Up Machine was using temporary wiring, a relocatable power tap was being used as a substitute for permanent wiring.