UTICA, NY —
OSHA Inspection: THE INDIUM CORPORATION OF AMERICA
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of THE INDIUM CORPORATION OF AMERICA in 111 BUSINESS PARK DRIVE, UTICA, NY 13502 (NAICS 331491). OSHA activity number 344469499.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE INDIUM CORPORATION OF AMERICA
- Site address
- 111 BUSINESS PARK DRIVE
- City
- UTICA
- State
- NY
- ZIP
- 13502
- Mailing
- 111 BUSINESS PARK DRIVE, UTICA, NY 13502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331491
- Employees
- 300
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.217 C01 I
- Issued
- Mar 30, 2020
- Penalty
- Initial $8,193 · Current $6,145 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): a) Indium Cell Area, on or about 11/26/20: Bench Master Punch Press PNCH019 point of operation was not adequately guarded, the opening at the front measured 2.5-inches x 12-inches.
Recent events (2)
- — I (S) $6144.75
- — Z (S) $8193
1910.303 B02
- Issued
- Mar 30, 2020
- Penalty
- Initial $4,178 · Current $3,134 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) S3 Nanofoil Area, on or about 11/22/19: A flexible cord with a quad metal receptacle box attached was used to provide power to a Shop Vacuum . The metal box is listed for permanent mounting only.
Recent events (2)
- — I (S) $3133.5
- — Z (S) $4178
1910.305 G01 IV A
- Issued
- Mar 30, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: a) Extrusion Area, on or about 11/22/19: Racine 50 Ton No. 1, Rotary Pan Take Up Machine was using temporary wiring, a relocatable power tap was being used as a substitute for permanent wiring.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at The Indium Corporation of America
View The Indium Corporation of America's full OSHA safety record →
More inspections in this industry (NAICS 331491)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344469499.