FRANKLIN PARK, IL —
OSHA Inspection: VORTEQ COIL FINISHERS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of VORTEQ COIL FINISHERS, LLC in 11440 ADDISON AVE, FRANKLIN PARK, IL 60131 (NAICS 332116). OSHA activity number 344469846.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VORTEQ COIL FINISHERS, LLC
- Site address
- 11440 ADDISON AVE
- City
- FRANKLIN PARK
- State
- IL
- ZIP
- 60131
- Mailing
- 11440 ADDISON AVE, FRANKLIN PARK, IL 60131
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 34
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Apr 27, 2020
- Abate by
- Aug 28, 2020
- Penalty
- Initial $48,195 · Current $20,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Paint Line- On or about November 13, 2019, the employer failed to ensure that hazards created by in-running nip points within the Accumulator Tower were guarded to prevent injury to employees. Employees were exposed to the in-running nip points while aligning the material using the screw adjustors for the rollers. b) Paint Line- On or about December 10, 2019, the employer failed to ensure that hazards created by in-running nip points within the Accumulator Tower were guarded to prevent injury to employees. Employees were exposed to the in-running nip points while aligning the material using the screw adjustors for the rollers. No abatement certification or documentation is required for this item. Vorteq Coil Finishers, LLC was previously cited for a violation of an equivalent Occupational Safety and Health Standard 1910.212(a)(1), which was contained in OSHA inspection number 1402832, citation number 1, item number 1 and was affirmed as a final order on September 6, 2019, with respect to a workplace located at 930 Armour Road in Oconomowoc, Wisconsin.
Recent events (2)
- — I (R) $20000
- — Z (R) $48195
1910.147 C04 I
- Issued
- Apr 27, 2020
- Abate by
- Jul 28, 2020
- Penalty
- Initial $13,494 · Current $9,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Print Line - On or about November 13, 2019, the employer failed to develop and utilize machine specific procedures to control the potentially hazardous energy for machines, such as the Accumulator Tower and the Print Line. This failure prevented employees from knowing the proper information on how to shut down and secure all sources of energy, such as electrical and potential gravitational energy. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $9500
- — Z (S) $13494
More inspections at Vorteq Coil Finishers, LLC
View Vorteq Coil Finishers, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332116)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344469846.