Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VARGAS REMODELING, LLC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of VARGAS REMODELING, LLC in 12120 SPRINGFIELD PIKE, SPRINGDALE, OH 45246 (NAICS 238170). OSHA activity number 344474903.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vargas Remodeling, LLC for free Get an email when a new federal OSHA severe-injury report for Vargas Remodeling, LLC is published. One employer, no account, unsubscribe in one click.
Site address
12120 SPRINGFIELD PIKE
City
SPRINGDALE
State
OH
ZIP
45246
Mailing
2718 HOUNZ LANE, LOUISVILLE, KY 40223
Inspection type
Programmed Related (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
Private (A)

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 28, 2020
Abate by
Feb 14, 2020
Penalty
Initial $4,048 · Current $2,024 Reduced
29 CFR 1926.20(b)(2): Accident prevention responsibilities. Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.         a)      On or about 11/25/2019 there was no frequent and regular inspection program being maintained in use by a competent person to ensure the job site, material and equipment; such as fall protection systems; and ladders.
Recent events (2)
  • · I (S) $2024
  • · Z (S) $4048

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 28, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.                a) On or about 11/25/2019 employees were installing siding on top of a lower level roof at a commercial property. Employees were not utilizing fall protection system, while working 19.1 ft. from the ground.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4048

1926.503 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 28, 2020
Abate by
Feb 14, 2020
Penalty
Initial $4,048 · Current $2,024 Reduced
29 CFR 1926.503(a)(1): "Training program". The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.       a)     On or about 11/25/2019 employees have not been trained on fall protection systems and on hazards of falls, while working at heights of 19ft.
Recent events (2)
  • · I (S) $2024
  • · Z (S) $4048

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 28, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.1053(b)(1): Use. The following requirements apply to the use of all ladders, including job-made ladders, except as otherwise indicated: When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.            a) On or about 11/25/2019 employees were accessing and exiting the roof by utilizing an extension ladder. The extension ladder did not extended at least 3 feet above the upper landing. The ladder was not secure on top to a rigid support.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4048

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344474903.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.