BOSTON, MA —
OSHA Inspection: COUGHLIN MASONRY RESTORATION CORP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COUGHLIN MASONRY RESTORATION CORP in 101 TOWNSEND ST, BOSTON, MA 02121 (NAICS 238140). OSHA activity number 344475447.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COUGHLIN MASONRY RESTORATION CORP
- Site address
- 101 TOWNSEND ST
- City
- BOSTON
- State
- MA
- ZIP
- 02121
- Mailing
- 4 VICTOR CIRCLE, PEABODY, MA 01960
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 E09 I
- Issued
- Jan 10, 2020
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.451(e)(9)(i): The employer did not provide safe means of access for each employee erecting or dismantling a scaffold: Location: 101 Townsend St. Employees were exposed to fall hazards while climbing down the frames of an approximately 50 feet high metal frame scaffold system where a safe means of access was not installed
Recent events (1)
- — Z (S) $2842
1926.451 F06
- Issued
- Jan 10, 2020
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. Location: 101 Townsend St. Employees were exposed to electrical shock hazards while repairing a masonry wall on a metal frame scaffold system where the metal frames of the scaffold system were approximately one foot from unguarded, active power transmission lines.