HOUSTON, TX ·
OSHA Inspection: CONCHA GUZMAN
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CONCHA GUZMAN in 6815 SPINDLE DR., HOUSTON, TX 77086 (NAICS 327991). OSHA activity number 344475934.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONCHA GUZMAN
- Site address
- 6815 SPINDLE DR.
- City
- HOUSTON
- State
- TX
- ZIP
- 77086
- Mailing
- 6815 SOINDLE DRIVE, HOUSTON, TX 77086
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 3
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.134 D01 III
- Issued
- Apr 13, 2020
- Abate by
- May 29, 2020
- Penalty
- Initial $2,313 · Current $2,313
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form. On or about November 25, 2019, in the granite grinding area, employees were required to wear a half-face respirator with P-A-1 filters when performing grinding tasks without the employer identifying and evaluating the respiratory hazards in the workplace.
Recent events (1)
- · Z (S) $2313
1910.134 E01
- Issued
- Apr 13, 2020
- Abate by
- May 29, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. On or about November 25, 2019, in the granite grinding area, employees were required to wear a half-face respirator with P-A-1 filters when performing grinding tasks without a medical evaluation.
Recent events (1)
- · Z (S) $0
1910.134 F02
- Issued
- Apr 13, 2020
- Abate by
- May 29, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator. On or about November 25, 2019, in the granite grinding area, employees were required to wear a half-face respirator with P-A-1 filters when performing grinding tasks without a respirator fit test.
Recent events (1)
- · Z (S) $0
1910.305 B01 II
- Issued
- Apr 13, 2020
- Abate by
- May 29, 2020
- Penalty
- Initial $2,892 · Current $2,892
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about November 25, 2019, in the granite grinding area, where employees are exposed to electrical hazard(s) when accessing the breaker panel without blanks being installed where there are unused openings.
Recent events (1)
- · Z (S) $2892
1910.305 B02
- Issued
- Apr 13, 2020
- Abate by
- May 29, 2020
- Penalty
- Initial $2,313 · Current $2,313
General-duty citation text
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose On or about November 25, 2019, in the outdoor granite grinding area, employees were exposed to electrical hazards while working near a mounted pull box without a cover.
Recent events (1)
- · Z (S) $2313
1910.334 A02 II
- Issued
- Apr 13, 2020
- Abate by
- May 29, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service. On or about November 25, 2019, in the granite grinding area, employees were operating equipment with a damaged electrical extension cord that did not have strain relief.