NEW YORK, NY —
OSHA Inspection: BULLS EYE CONTRACTOR INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BULLS EYE CONTRACTOR INC. in 501 WEST 144TH STREET, NEW YORK, NY 10031 (NAICS 238140). OSHA activity number 344478805.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BULLS EYE CONTRACTOR INC.
- Site address
- 501 WEST 144TH STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10031
- Mailing
- 95-29 113TH STREET, SOUTH RICHMOND HILL, NY 11419
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 D05 III
- Issued
- Feb 28, 2020
- Abate by
- Mar 5, 2020
- Penalty
- Initial $2,892 · Current $2,892
General-duty citation text
29 CFR 1926.451(d)(5)(iii): Opposing angle tiebacks were not installed and not secured to a structurally sound point of anchorage on the building or structure. Sound points of anchorage include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit. Location: a) Suspended scaffold on the northwest side of the jobsite: On or about 11/26/2019, an employee was repairing the exterior wall of the building by working on a suspended scaffold. The suspended scaffold tiebacks were installed and secured to guardrails piping and electrical equipment mounting pipes. They were not structurally sound point of anchorage.
Recent events (1)
- — Z (S) $2892
1926.451 E01
- Issued
- Feb 28, 2020
- Abate by
- Mar 5, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Location: a) Sidewalk shed on the southwest side of the jobsite: On or about 11/26/2019, employees climbed fences and scaffold bracing as a mean of access to access the sidewalk shed level.
Recent events (1)
- — Z (S) $4048
1926.451 G01 VII
- Issued
- Feb 28, 2020
- Abate by
- Mar 5, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: a) Sidewalk shed on the southwest side of the jobsite: On or about 11/26/2019, employees were accessing the suspended scaffold from the sidewalk shed, and there was an opening next to the access point that exposed employees to falling approximately 15 feet to the ground level. The employees were not protected from fall by the use of personal fall arrest systems, or guardrail systems.
Recent events (1)
- — Z (S) $4048
1926.1053 B01
- Issued
- Feb 28, 2020
- Abate by
- Mar 5, 2020
- Penalty
- Initial $2,892 · Current $2,892
General-duty citation text
29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed; the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. Location: a) Sidewalk shed on the southwest side of the jobsite: On or about 11/26/2019, employees used a folded A-frame ladder for access between the lower sidewalk shed and to the upper sidewalk shed. The ladder was not extended at least three feet above the landing being accessed and was not secured at its top.
Recent events (1)
- — Z (S) $2892
1926.1053 B04
- Issued
- Feb 28, 2020
- Abate by
- Mar 5, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed. Location: a) Sidewalk shed on the southwest side of the jobsite: On or about 11/26/2019, employees used a folded A-frame ladder for access between the lower sidewalk shed and to the upper sidewalk shed. The ladder was not designed to be climbed while it is folded.
Recent events (1)
- — Z (S) $0
More inspections at Bulls EYE Contractor INC.
View Bulls EYE Contractor INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344478805.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.