OSHA Inspection: GEER NURSING AND REHABILITATION CENTER

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GEER NURSING AND REHABILITATION CENTER in 99 SOUTH CANAAN ROAD, NORTH CANAAN, CT 06018 (NAICS 623110). OSHA activity number 344484407.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Geer Nursing and Rehabilitation Center for free Get an email when a new federal OSHA severe-injury report for Geer Nursing and Rehabilitation Center is published. One employer, no account, unsubscribe in one click.
Site address
99 SOUTH CANAAN ROAD
City
NORTH CANAAN
State
CT
ZIP
06018
Mailing
99 SOUTH CANAAN ROAD, NORTH CANAAN, CT 06018
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
200
Ownership type
Private (A)

10 citations on file for this inspection.

1910.36 H02

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 27, 2020
Abate by
Feb 10, 2020
Penalty
Initial $4,424 · Current $3,097 Reduced
29 CFR 1910.36(h)(2): The outdoor exit route was not covered and snow or ice had accumulated along the route, creating a slipping hazard:  Boiler room rear exit: On or about December 3, 2019, the exit landing and ascending stairway leading out of the boiler room was covered with snow and ice.
Recent events (2)
  • · I (S) $3096.8
  • · Z (S) $4424

1910.37 A03

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  On or about, December 3, 2019, in the following instances exit routes were not kept free and unobstructed.  1. Main building boiler room rear:  A five gallon bucket was blocking access to the exit door.  2. Maintenance building second floor rear: The exit was blocked by an engineered beam and a small pile of floor tiles.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.37 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 27, 2020
Abate by
Mar 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that employees with normal vision could see along the exit route:    Maintenance building back exit landing: On or about December 3, 2019, the exit stair leading from the second floor to the first floor exit was not adequately lighted.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.37 B02

Serious Gravity 1 3 instances 3 exposed
Issued
Jan 27, 2020
Abate by
Mar 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  On or about December 3, 2019, in the following instances exits were not clearly visible:  1. Maintenance building rear exit landing: there was no exit sign present indicating that this door led to the outside as an emergency exit.   2. Maintenance building second floor: there was no exit sign present in the area of the top of the stair case leading to the first floor exit.  3. Maintenance building first floor: front stair landing, there was no exit sign above the exit at this location.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.37 B05

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 27, 2020
Abate by
Mar 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):   Maintenance building first floor rear stair landing: On or about December 3, 2019, a door at the bottom of an exit egress led back into the building and was not marked "Not an Exit".
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.101 B

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 27, 2020
Abate by
Mar 13, 2020
Penalty
Initial $4,424 · Current $3,097 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  Maintenance building first floor back room: On or about December 3, 2019, two oxygen cylinders and one carbon dioxide cylinder were stored in this area unsecured.
Recent events (2)
  • · I (S) $3096.8
  • · Z (S) $4424

1910.102 A

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 27, 2020
Abate by
Mar 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.102(a): The in-plant transfer, handling, storage, and utilization of acetylene in cylinders was not in accordance with Compressed Gas Association Pamphlet G-1-1966, which is incorporated by reference as specified in 29 CFR 1910.6:  Maintenance building first floor: On or about December 3, 2019, an acetylene tank was not secured properly. The acetylene cylinder was found standing upright unsecured near flammable and combustible material.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 27, 2020
Abate by
Mar 13, 2020
Penalty
Initial $5,899 · Current $4,129 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Boiler room rear area: On or about December 3, 2019, an air compressor used to augment the sprinkler system pressure was unguarded. There was a two foot by 19 inch opening to the spoked pulley located on the floor. Possible amputations, crush injuries, or avulsions are possible if an employees hand would get caught the compressor.
Recent events (2)
  • · I (S) $4129.3
  • · Z (S) $5899

1910.303 G01 II

Other-than-serious 1 instance 3 exposed
Issued
Jan 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  On or about, December 3, 2019, working space in front of electrical equipment was used for storage.   1. Main Building Laundry: A laundry rack of unclaimed clothing was stored in front of 120/208 volt panel.   2. Main building boiler room, front: A long cardboard box and a long metal pipe were stored in front of the I-T-E 120/208 volt electric panel.   3. Maintenance building second floor:  A plastic bin was stored in front of the load center panel.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 G01 III

Other-than-serious 1 instance 3 exposed
Issued
Jan 27, 2020
Abate by
Feb 10, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(iii): The employer did not ensure that at least one entrance of sufficient area was provided to give access to the working space about electric equipment 600 Volts, nominal, or less.  Main building boiler room, rear: On or about December 3, 2019, a rolling tool box was stored in front of the GE 120/208 volt electric panel limiting access.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344484407.