WACO, TX —
OSHA Inspection: ELCO POWDER COATING
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ELCO POWDER COATING in 3519 INTERSTATE 35, WACO, TX 76710 (NAICS 325510). OSHA activity number 344487194.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELCO POWDER COATING
- Site address
- 3519 INTERSTATE 35
- City
- WACO
- State
- TX
- ZIP
- 76710
- Mailing
- 3519 INTERSTATE 35, WACO, TX 76710
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 7
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 C01
- Issued
- Jan 31, 2020
- Abate by
- Mar 2, 2020
- Penalty
- Initial $2,313 · Current $1,388 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures: On or about December 03, 2019, and at times prior thereto, at a workplace located at 3519 Interstate 35, Waco, Texas; the employer did not establish and implement a written respiratory protection program for employees wearing respirators to perform powder coating operations.
Recent events (2)
- — I (S) $1387.8
- — Z (S) $2313
1910.134 E01
- Issued
- Jan 31, 2020
- Abate by
- Mar 2, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about December 03, 2019, and at times prior thereto, at a workplace located at 3519 Interstate 35, Waco, Texas; the employer did not provide medical evaluation to employees required to use respirators, exposing employees to physiological hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Jan 31, 2020
- Abate by
- Mar 2, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirators is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: On or about December 03, 2019, and at times prior thereto, at a workplace located at 3519 Interstate 35, Waco, Texas; employees required to use respirators were not fit tested prior to respirator use and annually.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Jan 31, 2020
- Abate by
- Mar 2, 2020
- Penalty
- Initial $2,313 · Current $1,388 Reduced
General-duty citation text
29 CFR 1910. 151(c): Where the eyes and body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body was not provided within the work area for immediate emergency use: On or about December 03, 2019, and at times prior thereto, at a workplace located at 3519 Interstate 35, Waco, Texas; employees using corrosive chemicals were not provided with an eye wash station within the spray area for immediate flushing of the eyes in an emergency exposing employees to eye and skin injuries.
Recent events (2)
- — I (S) $1387.8
- — Z (S) $2313
1910.157 C04
- Issued
- Jan 31, 2020
- Abate by
- Mar 2, 2020
- Penalty
- Initial $2,313 · Current $1,388 Reduced
General-duty citation text
29 CFR 1910.157(c)(4): The employer did not assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use: On or about December 03, 2019, and at times prior thereto, at a workplace located at 3519 Interstate 35, Waco, Texas; wall mounted portable fire extinguishers in the production department had not been re-charged in more than three years according to the inspection tags.
Recent events (2)
- — I (S) $1387.8
- — Z (S) $2313
1910.303 E01 II
- Issued
- Jan 31, 2020
- Abate by
- Mar 2, 2020
- Penalty
- Initial $2,313 · Current $1,388 Reduced
General-duty citation text
29 CFR 1910. 303(e)(1)(ii): Markings were not provided for voltage, current, wattage, and other ratings as necessary: On or about December 03, 2019, and at times prior thereto, at a workplace located at 3519 Interstate 35, Waco, Texas; the employer had electrical panel boxes that were not labeled or marked with the voltage ratings.
Recent events (2)
- — I (S) $1387.8
- — Z (S) $2313
1910.1200 E01
- Issued
- Jan 31, 2020
- Abate by
- Mar 2, 2020
- Penalty
- Initial $1,735 · Current $1,041 Reduced
General-duty citation text
29 CFR 1910. 1200(e)(1): Employer did not develop, implement, and maintain at each work place, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning: On or about December 03, 2019, and at times prior thereto, at a workplace located at 3519 Interstate 35, Waco, Texas; the employer did not ensure that a written hazard communication program with all the required elements was available at the workplace for employees using chemicals such as Barium Sulfate.
Recent events (2)
- — I (S) $1041
- — Z (S) $1735
More inspections at Elco Powder Coating
View Elco Powder Coating's full OSHA safety record →
More inspections in this industry (NAICS 325510)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344487194.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.