COLUMBUS, OH —
OSHA Inspection: RESTAURANT DEPOT LLC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of RESTAURANT DEPOT LLC. in 270 NORTH WILSON ROAD, COLUMBUS, OH 43204 (NAICS 493120). OSHA activity number 344488457.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RESTAURANT DEPOT LLC.
- Site address
- 270 NORTH WILSON ROAD
- City
- COLUMBUS
- State
- OH
- ZIP
- 43204
- Mailing
- 270 NORTH WILSON ROAD, COLUMBUS, OH 43204
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493120
- Employees
- 47
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 A04
- Issued
- Feb 21, 2020
- Abate by
- Mar 12, 2020
- Penalty
- Initial $10,603 · Current $10,603
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly. a. On or about November 22, 2019, an employee was elevated in Aisle 4B area on the forks of a RR6000 Series Crown High-Low electric motor narrow aisle forklift. The employee was exposed to a fall hazard of approximately 9 feet while lifted up to the second bay of the warehouse storage shelving in the area to obtain product for a customer. b. On or about November 26, 2019, an employee was elevated in the Freezer Area while standing on the forks of a RR6000 Series Crown High-Low electric motor narrow aisle forklift. The employee was exposed to a fall hazard of approximately 9 feet while lifted up to the second bay of the warehouse storage shelving in order to obtain product for a customer. c. On or about November 26, 2019, an employee was elevated in the Freezer Area while standing on a blue pallet (chap) lifted by the forks of a RR6000 Series Crown High-Low electric motor narrow aisle forklift. The employee was exposed to a fall hazard of approximately 9 feet while lifted up to the second bay of the warehouse storage shelving in order to obtain product for a customer.
Recent events (2)
- — I (S) $10603
- — Z (S) $10603
1910.303 G01 II
- Issued
- Feb 21, 2020
- Abate by
- Mar 4, 2020
- Penalty
- Initial $6,361 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded. a. On or about December 9, 2019, there were three 120/208 Volt electrical panels in the Manager's office that had materials stored within the required working space. The storage of fans, boxes, and other equipment was on and directly under the electrical panels blocking them from being safely accessed.
Recent events (2)
- — I (O) $0
- — Z (S) $6361
1910.303 G02 I
- Issued
- Feb 21, 2020
- Abate by
- Mar 12, 2020
- Penalty
- Initial $8,482 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: a. On or about December 9, 2019 and at times prior, there was a 460-Volt damaged electrical box at the control station for the Compactor in the Receiving Department, which exposed employees to an electrical shock hazard. The electrical box was at waist height and the door was not latched close and live electrical parts were exposed.
Recent events (2)
- — I (O) $0
- — Z (S) $8482
More inspections at Restaurant Depot LLC.
View Restaurant Depot LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 493120)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344488457.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.