Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RESTAURANT DEPOT LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RESTAURANT DEPOT LLC. in 270 NORTH WILSON ROAD, COLUMBUS, OH 43204 (NAICS 493120). OSHA activity number 344488457.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Restaurant Depot LLC. — free Get an email when a new federal OSHA severe-injury report for Restaurant Depot LLC. is published. One employer, no account, unsubscribe in one click.
Site address
270 NORTH WILSON ROAD
City
COLUMBUS
State
OH
ZIP
43204
Mailing
270 NORTH WILSON ROAD, COLUMBUS, OH 43204
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
47
Ownership type
A

3 citations on file for this inspection.

1910.178 A04

Serious Gravity 5 3 instances 3 exposed
Issued
Feb 21, 2020
Abate by
Mar 12, 2020
Penalty
Initial $10,603 · Current $10,603
29 CFR 1910.178(a)(4):   Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly.  a.    On or about November 22, 2019, an employee was elevated in Aisle 4B area on the forks of a RR6000 Series Crown High-Low electric motor narrow aisle forklift. The employee was exposed to a fall hazard of approximately 9 feet while lifted up to the second bay of the warehouse storage shelving in the area to obtain product for a customer.  b.    On or about November 26, 2019, an employee was elevated in the Freezer Area while standing on the forks of a RR6000 Series Crown High-Low electric motor narrow aisle forklift. The employee was exposed to a fall hazard of approximately 9 feet while lifted up to the second bay of the warehouse storage shelving in order to obtain product for a customer.  c.    On or about November 26, 2019, an employee was elevated in the Freezer Area while standing on a blue pallet (chap) lifted by the forks of a RR6000 Series Crown High-Low electric motor narrow aisle forklift. The employee was exposed to a fall hazard of approximately 9 feet while lifted up to the second bay of the warehouse storage shelving in order to obtain product for a customer.
Recent events (2)
  • — I (S) $10603
  • — Z (S) $10603

1910.303 G01 II

Other-than-serious 1 instance 3 exposed
Issued
Feb 21, 2020
Abate by
Mar 4, 2020
Penalty
Initial $6,361 · Current $0 Reduced
29 CFR 1910.303(g)(1)(ii): Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded.  a. On or about December 9, 2019, there were three 120/208 Volt electrical panels in the Manager's office that had materials stored within the required working space. The storage of fans, boxes, and other equipment was on and directly under the electrical panels blocking them from being safely accessed.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6361

1910.303 G02 I

Other-than-serious 1 instance 5 exposed
Issued
Feb 21, 2020
Abate by
Mar 12, 2020
Penalty
Initial $8,482 · Current $0 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:  a. On or about December 9, 2019 and at times prior, there was a 460-Volt damaged electrical box at the control station for the Compactor in the Receiving Department, which exposed employees to an electrical shock hazard. The electrical box was at waist height and the door was not latched close and live electrical parts were exposed.