MADISON, WI —
OSHA Inspection: SUB-ZERO, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of SUB-ZERO, INC. in 6061 BASSWOOD DRIVE, MADISON, WI 53719 (NAICS 335222). OSHA activity number 344494893.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUB-ZERO, INC.
- Site address
- 6061 BASSWOOD DRIVE
- City
- MADISON
- State
- WI
- ZIP
- 53719
- Mailing
- 6061 BASSWOOD DRIVE, MADISON, WI 53719
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335222
- Employees
- 850
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Apr 24, 2020
- Abate by
- May 8, 2020
- Penalty
- Initial $13,494 · Current $13,494
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about December 06, 2019 lockout procedures were not developed for Bystronic laser employees: a. entering the material handling area and performing work beneath the material handling lift. b. adjusting material handling lift suction cups vacuum spigots.
Recent events (1)
- — Z (S) $13494
1910.147 D03
- Issued
- Apr 24, 2020
- Abate by
- May 8, 2020
- Penalty
- Initial $13,494 · Current $13,494
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about December 06, 2019 energy isolating devices were not used to de-energize the Bystronic Laser Fiber when: a. entering the material handling area and working under the material handling lift. b. adjusting material handling lift suction cups vacuum spigots.
Recent events (1)
- — Z (S) $13494
1910.147 D04 I
- Issued
- Apr 24, 2020
- Abate by
- May 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about December 06, 2020 laser operator did not affix energy control devices to Bystroninc laser material handling lifts when employees: a. entered the material handling area and performed work beneath the material handling lift. b. adjusting material handling lift suction cups vacuum spigots.
Recent events (1)
- — Z (S) $0
More inspections at Sub-Zero, INC.
View Sub-Zero, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 335222)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344494893.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.