OSHA Inspection: SUB-ZERO, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SUB-ZERO, INC. in 6061 BASSWOOD DRIVE, MADISON, WI 53719 (NAICS 335222). OSHA activity number 344494893.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sub-Zero, INC. — free Get an email when a new federal OSHA severe-injury report for Sub-Zero, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SUB-ZERO, INC.
Site address
6061 BASSWOOD DRIVE
City
MADISON
State
WI
ZIP
53719
Mailing
6061 BASSWOOD DRIVE, MADISON, WI 53719
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335222
Employees
850
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 24, 2020
Abate by
May 8, 2020
Penalty
Initial $13,494 · Current $13,494
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about December 06, 2019 lockout procedures were not developed for Bystronic laser employees: a. entering the material handling area and performing work beneath the material handling lift.   b. adjusting material handling lift suction cups vacuum spigots.
Recent events (1)
  • — Z (S) $13494

1910.147 D03

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 24, 2020
Abate by
May 8, 2020
Penalty
Initial $13,494 · Current $13,494
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  On or about December 06, 2019 energy isolating devices were not used to de-energize the Bystronic Laser Fiber when: a. entering the material handling area and working under the material handling lift.   b. adjusting material handling lift suction cups vacuum spigots.
Recent events (1)
  • — Z (S) $13494

1910.147 D04 I

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 24, 2020
Abate by
May 8, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about December 06, 2020 laser operator did not affix energy control devices to Bystroninc laser material handling lifts when employees: a. entered the material handling area and performed work beneath the material handling lift.   b. adjusting material handling lift suction cups vacuum spigots.