NORTH TONAWANDA, NY —
OSHA Inspection: PELLETS LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PELLETS LLC in 63 INDUSTRIAL DR. SUITE 3, NORTH TONAWANDA, NY 14120 (NAICS 327910). OSHA activity number 344495890.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PELLETS LLC
- Site address
- 63 INDUSTRIAL DR. SUITE 3
- City
- NORTH TONAWANDA
- State
- NY
- ZIP
- 14120
- Mailing
- 63 INDUSTRIAL DR. SUITE 3, NORTH TONAWANDA, NY 14120
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327910
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.37 A03
- Issued
- Apr 16, 2020
- Penalty
- Initial $2,621 · Current $2,621
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) On or about 12/16/19 - The shop exit door was blocked by a snow blower. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2621
- — Z (S) $2621
1910.215 B01
- Issued
- Apr 16, 2020
- Abate by
- May 18, 2020
- Penalty
- Initial $2,622 · Current $2,629
General-duty citation text
29 CFR 1910.215(b)(1): Cup wheel(s) of grinder(s) were not protected by guards: (a) Cincinnati cutter and tool grinder - On or about 12/16/19, the cup wheel was not protected by a guard. The motor operates at 1850 rpm. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2629
- — Z (S) $2622
1910.219 D01
- Issued
- Apr 16, 2020
- Penalty
- Initial $2,622 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Cincinnati cutter and tool grinder - On or about 12/16/19, the two pulleys with parts seven feet or less from the floor were not guarded. The motor operates at 1850 rpm. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $2622
1910.219 E01 I
- Issued
- Apr 16, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt or to a standard height: (a) Cincinnati cutter and tool grinder - On or about 12/16/19, the horizontal belt with both run seven feet or less from the floor was not guarded. The motor operates at 1850 rpm. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Apr 16, 2020
- Abate by
- May 18, 2020
- Penalty
- Initial $2,622 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Shop shipping area - On or about 3/10/20, a Dell computer monitor (operating at 115 volts and 0.1 amperes) was connected to a relocatable power strip (operating at 115 volts and 15 amperes). The power strip was hanging on the wall. The relocatable power strip was not used or installed in accordance with instructions included in the listing or labeling. (b) Shop shipping area - On or about 3/10/20, a Dell computer monitor (operating at 115 volts and 0.1 amperes) was connected to a relocatable power strip (operating at 115 volts and 15 amperes). The relocatable power strip and the SWS LP7510 LED Scale Weighing System (operating at 115 volts and 0.1 ampere) were plugged into a triple outlet adapter. The triple outlet adapter was plugged into a dual outlet receptacle (operating at 115 volts). The triple outlet adapter was not used or installed in accordance with instructions included in the listing or labeling. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $2622
More inspections at Pellets LLC
View Pellets LLC's full OSHA safety record →
More inspections in this industry (NAICS 327910)
More inspections in NY
Source