WARREN, OH —
OSHA Inspection: ARCELORMITTAL CLEVELAND, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of ARCELORMITTAL CLEVELAND, LLC in 2234 MAIN AVENUE SW, WARREN, OH 44481 (NAICS 331110). OSHA activity number 344497011.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCELORMITTAL CLEVELAND, LLC
- Site address
- 2234 MAIN AVENUE SW
- City
- WARREN
- State
- OH
- ZIP
- 44481
- Mailing
- 3060 EGGERS AVENUE, CLEVELAND, OH 44105
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331110
- Employees
- 173
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- May 14, 2020
- Penalty
- Initial $12,145 · Current $8,501 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: On or about December 3, 2019 employees were exposed to coke oven gas containing high levels of carbon monoxide during the isolation and blanking of gas lines. Two employees were overexposed to carbon monoxide gas.
Recent events (2)
- — I (S) $8501
- — Z (S) $12145
1910.147 D
- Issued
- May 14, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about December 3, 2019 employees were exposed to coke oven gas containing high levels of carbon monoxide during the isolation and blanking of gas lines. The employer failed to implement energy control application steps as LOTO devices were not applied to lock open the water lines hooked up to water seal valves [per 1910.147(d)(4) requirements.] As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Arcelormittal Cleveland, LLC
View Arcelormittal Cleveland, LLC's full OSHA safety record →
More inspections in this industry (NAICS 331110)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344497011.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.