Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: ALCON MECHANICAL PIPING, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ALCON MECHANICAL PIPING, INC. in 1932 WARREN AVE, NILES, OH 44446 (NAICS 238220). OSHA activity number 344501044.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alcon Mechanical Piping, INC. for free Get an email when a new federal OSHA severe-injury report for Alcon Mechanical Piping, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1932 WARREN AVE
City
NILES
State
OH
ZIP
44446
Mailing
1932 WARREN AVE, NILES, OH 44446
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
35
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
May 14, 2020
Penalty
Initial $9,446 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.   On or about December 3, 2019, written procedures for isolation and blanking steam boosters lacked specific steps for isolating coke oven gas in that it did not require lines supplying water to water seal valves to be locked open.
Recent events (2)
  • · I (S) $0
  • · Z (S) $9446

1910.147 D

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
May 14, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   On or about December 3, 2019, employees were exposed to hazardous coke oven gas during the isolation and blanking of gas lines. The employer failed to implement energy control application steps as LOTO devices were not applied to lock open the water seal valves [per 1910.147(d)(4) requirements.] As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.    LOTO device application [(d)(4)] - Affix a lockout or tagout device to each energy isolating device;   dissipation of residual energy [(d)(5)(i)] - relieve, disconnect, restrain, and otherwise  render safe all potentially hazardous stored or residual energy;   verification of isolation [(d)(6)] - Verify that isolation and deenergization of the machine or equipment has been accomplished.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
May 14, 2020
Penalty
Initial $9,446 · Current $9,446
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:    On or about December 3, 2019 employees were exposed to coke oven gas containing high levels of carbon monoxide during the isolation and blanking of gas lines. Two employees were overexposed to carbon monoxide gas.
Recent events (2)
  • · I (S) $9446
  • · Z (S) $9446

1910.1000 E

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
May 14, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):   a. On or about December 3, 2019, an employee tasked with isolating and blanking the steam booster was exposed to an 8-hour time weighted average (TWA) of 103.9 parts per million (ppm) for carbon monoxide, approximately 2.08 times the Permissible Exposure Limit (PEL) of 50 ppm. The exposure level was derived utilizing a carboxyhemoglobin calculation which utilized medical information to calculate a 15 minute exposure with zero exposure assumed for the remaining period of 465 minutes.     b. On or about December 3, 2019, an employee tasked with isolating and blanking the steam booster was exposed to an 8-hour time weighted average (TWA) of 92.8 parts per million (ppm) for carbon monoxide, approximately 1.86 times the Permissible Exposure Limit (PEL) of 50 ppm. The exposure level was derived utilizing a carboxyhemoglobin calculation which utilized medical information to calculate a 15 minute exposure with zero exposure assumed for the remaining period of 465 minutes.   The employer did not ensure that employees were not exposed to carbon monoxide above the OSHA PEL of 50 ppm by means of administrative or engineering controls.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344501044.