Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: SOUTH CENTRAL STEEL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SOUTH CENTRAL STEEL, INC. in 3504 HIGHWAY 280 E, HARPERSVILLE, AL 35078 (NAICS 332312). OSHA activity number 344507298.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch South Central Steel, INC. for free Get an email when a new federal OSHA severe-injury report for South Central Steel, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3504 HIGHWAY 280 E
City
HARPERSVILLE
State
AL
ZIP
35078
Mailing
3504 HIGHWAY 280 E, HARPERSVILLE, AL 35078
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
28
Ownership type
Private (A)

6 citations on file for this inspection.

1910.219 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 13, 2020
Penalty
Initial $4,588 · Current $2,753 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one-half the diameter of the shaft:  (a) On or about 12/12/2019 - Lower Shop at Crossover Beam Area, employees were exposed to caught-in hazards when unguarded projecting shaft end rods projected more than one-half the diameter of the shaft into the walkways at the Staging location entrance and the Peddinghaus outfeed conveyor.
Recent events (2)
  • · I (S) $2752.8
  • · Z (S) $4588

1910.219 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 13, 2020
Penalty
Initial $5,735 · Current $3,441 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:  (a) On or about 12/12/2019 - Lower Shop at Crossover Beam Area, employees were exposed to caught-in hazards when sprocket wheels and chains less than 31 inches from the floor were not enclosed at the Staging Area walkways.
Recent events (2)
  • · I (S) $3441
  • · Z (S) $5735

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 13, 2020
Abate by
May 7, 2020
Penalty
Initial $4,588 · Current $2,753 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  (a) On or about 12/12/2019 - Lower Shop at Peddinghaus machine, employees were exposed to electric shock hazards when using the Graco Magnum Projector Painter Plus equipment and the grounding prong was missing.
Recent events (2)
  • · I (S) $2752.8
  • · Z (S) $4588

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 13, 2020
Abate by
May 7, 2020
Penalty
Initial $4,588 · Current $2,753 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) On or about 12/12/2019 - Paint Bay, employees were exposed to arc flash or electrical shock hazards when an unused cabinet opening was not closed in the 240 volt breaker box panel.
Recent events (2)
  • · I (S) $2752.8
  • · Z (S) $4588

1910.305 G01 IV A

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 13, 2020
Abate by
May 7, 2020
Penalty
Initial $6,882 · Current $4,129 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) On or about 12/12/2019 - Lower Shop at Welder stations 1 & 2, employees were exposed to fire and electric shock hazards when flexible cords were connected in series with relocatable power taps and splitters to power equipment such as, but not limited to, portable grinders, microwaves, stereo, dusk-to-dawn light, and work lights and an extension cord had bare wires that had been covered with tape.  (b) On or about 12/12/2019 - Lower Shop at Paint Bay, employees were exposed to fire hazards when flexible cords were used to as a substitute for fixed wiring to power a dusk-to-dawn light and a 4-outlet receptacle that had a burn mark on one of the receptacles.
Recent events (2)
  • · I (S) $4129.2
  • · Z (S) $6882

1910.107 G07

Other-than-serious 1 instance 2 exposed
Issued
Apr 13, 2020
Abate by
May 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color background were not posted at all spraying areas and paint storage rooms:  (a) On or about 12/12/2019 - Paint Bay, employees were exposed to fire hazards when a "No smoking" sign was not posted in the spray area.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View South Central Steel, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344507298.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.