Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STRIVE CONSTRUCTION, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of STRIVE CONSTRUCTION, LLC in 556 ATWELLS AVE., PROVIDENCE, RI 02909 (NAICS 236118). OSHA activity number 344507736.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Strive Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Strive Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
556 ATWELLS AVE.
City
PROVIDENCE
State
RI
ZIP
02909
Mailing
566 SMITH ST., PROVIDENCE, RI 02908
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Apr 20, 2020
Abate by
May 13, 2020
Penalty
Initial $4,453 · Current $2,226 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:    (a) Southeast corner of the roof:  On or about 11/21/2019, a 2 foot diameter circular hole on the walking/working surface was not protected from falling through the hole, from the roof down to the 2nd floor, creating a fall hazard of approximately 35 feet high.
Recent events (2)
  • — I (S) $2226
  • — Z (S) $4453

1926.502 I03

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 20, 2020
Abate by
May 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees:  (a) Jobsite - Third Floor: On or about 11/21/2019, a 10 inch by 12 inch hole in the floor was covered with a piece of metal, which was not secured to prevent it from becoming displaced.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 I04

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 20, 2020
Abate by
May 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard:  (a) Jobsite - Third floor: On or about 11/21/2019, a 10 inch by 12 inch hole in the floor was covered with a piece of metal which was not marked with the word "Hole" or "Cover" to warn employees of the hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Strive Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344507736.