Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PARCO MANUFACTURING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PARCO MANUFACTURING, INC. in 3819 WHITE AVE., EAU CLAIRE, WI 54703 (NAICS 326199). OSHA activity number 344507751.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Parco Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Parco Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3819 WHITE AVE.
City
EAU CLAIRE
State
WI
ZIP
54703
Mailing
3819 WHITE AVE., EAU CLAIRE, WI 54703
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
19
Ownership type
A

9 citations on file for this inspection.

1910.110 F02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 17, 2020
Abate by
May 5, 2020
Penalty
Initial $3,084 · Current $2,159 Reduced
29 CFR 1910.110(f)(2)(i): Liquefied petroleum gas containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering from unauthorized persons:    (a) Shipping/receiving area; A liquid propane gas cylinder stored next to an overhead door was not protected from physical damage.
Recent events (2)
  • — I (S) $2158.8
  • — Z (S) $3084

1910.110 F02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 17, 2020
Abate by
May 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.110(f)(2)(ii): Liquefied petroleum gas container(s) stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people:  (a) Shipping/receiving area; A liquid propane gas cylinder was stored near an exit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II B

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 17, 2020
Abate by
May 15, 2020
Penalty
Initial $3,084 · Current $2,159 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    (a) Production area; The energy isolation procedure for Ameri-Can brand two-point vinyl welder's did not identify the specific steps/techniques to be used to lockout and/or securing pneumatic energy in a state of isolation during servicing, maintenance, and cleaning operations.
Recent events (2)
  • — I (S) $2158.8
  • — Z (S) $3084

1910.147 D04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 17, 2020
Abate by
May 15, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    (a) Production area; A lock was not affixed on the pneumatic energy isolation point of an Ameri-Can brand two-point vinyl welder during servicing, maintenance, and cleaning operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 17, 2020
Abate by
May 5, 2020
Penalty
Initial $3,084 · Current $2,159 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Production area; Guarding was not provided for rotating parts and flying chips on drill presses.
Recent events (2)
  • — I (S) $2158.8
  • — Z (S) $3084

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 17, 2020
Abate by
May 5, 2020
Penalty
Initial $2,313 · Current $1,620 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    (a) Production area; A flexible cord set (extension cord) and portable relocatable power tap were used in place of permanent wiring to supply electricity for battery chargers of cordless tools.
Recent events (2)
  • — I (S) $1619.6
  • — Z (S) $2313

1910.147 C06 II

Other-than-serious 1 instance 3 exposed
Issued
Apr 17, 2020
Abate by
Jun 16, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:    (a) Production area; A record of certification was not maintained for the periodic evaluation of lockout procedures for Ameri-Can brand two-point vinyl welder's.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C07 IV

Other-than-serious 1 instance 3 exposed
Issued
Apr 17, 2020
Abate by
Jun 19, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:    (a) Production area; A record of lockout training certification was not maintained to identify who received training.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L04 III

Other-than-serious 1 instance 3 exposed
Issued
Apr 17, 2020
Abate by
Jun 19, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years:    (a) Throughout the facility; Forklift operators did not have their ability to safely operate forklifts evaluated within the last three years.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0