Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ONEILL PRECISION COMPONENTS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ONEILL PRECISION COMPONENTS, INC. in 1090 3RD STREET, SUITE D, NORTH VERSAILLES, PA 15137 (NAICS 332710). OSHA activity number 344518212.

Watch Oneill Precision Components, INC. — free Get an email when a new federal OSHA severe-injury report for Oneill Precision Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1090 3RD STREET, SUITE D
City
NORTH VERSAILLES
State
PA
ZIP
15137
Mailing
1090 3RD STREET, SUITE D, NORTH VERSAILLES, PA 15137
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
2
Ownership type
A

2 citations on file for this inspection.

1910.151 C

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1735.00 · Current $0.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) In the facility, on or about December 18, 2019 - The employer did not ensure that employees exposed to injurious corrosive materials such as, but not limited to Cimclean Producto SP-603, were provided suitable facilities for quick drenching or flushing of the eyes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1735

1910.1200 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1735.00 · Current $1000.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement and maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g) and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met:    a) In the facility, on or about December 18, 2019 - The employer did not develop or maintain a written hazard communication program for employees exposed to hazardous chemicals in the workplace, such as, but not limited to Cimclean Producto SP-603.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1735

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344518212.