Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: BODIN'S, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BODIN'S, INC. in 208 WILSON AVE., BAYFIELD, WI 54814 (NAICS 311712). OSHA activity number 344529797.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bodin'S, INC. for free Get an email when a new federal OSHA severe-injury report for Bodin'S, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BODIN'S, INC.
Site address
208 WILSON AVE.
City
BAYFIELD
State
WI
ZIP
54814
Mailing
P.O. BOX 687, BAYFIELD, WI 54814
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311712
Employees
9
Ownership type
A

8 citations on file for this inspection.

1910.133 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 17, 2020
Abate by
Apr 14, 2020
Penalty
Initial $2,892 · Current $1,445 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:    (a) Production floor, forklift battery charging area(s); On or about December 5, 2019, an employee was not equipped with adequate eye or face protection when handling corrosive batteries for powered industrial truck(s).
Recent events (2)
  • · I (S) $1445
  • · Z (S) $2892

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 17, 2020
Abate by
Apr 14, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a) Production floor, forklift battery charging area(s); On or about December 5, 2019, facilities for quick drenching and flushing of the eyes were not provided within the immediate work area.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L01 II

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 17, 2020
Abate by
Apr 14, 2020
Penalty
Initial $2,313 · Current $1,445 Reduced
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck:    (a) Throughout the facility; The employer did not ensure each powered industrial truck operator was trained prior to operation.
Recent events (2)
  • · I (S) $1445
  • · Z (S) $2313

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 17, 2020
Abate by
Apr 14, 2020
Penalty
Initial $2,313 · Current $1,445 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:    (a) Herring processing area; The skinning blade located at the point of operation on the Trio Model FDS (S/N 476) fish  skinning machine was not effectively guarded.
Recent events (2)
  • · I (S) $1445
  • · Z (S) $2313

1910.219 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 17, 2020
Abate by
Apr 14, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:  (a) Herring processing area; A chain and sprocket mechanism located on the Trio Model FDS (S/N 476) fish skinning machine was not effectively guarded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Mar 17, 2020
Abate by
Apr 14, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Retail area; On or about October 20, 2019, a flexible electrical extension cord, used to supply power to an overhead fluorescent light fixture, was plugged into a relocatable power tap.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Mar 17, 2020
Abate by
Apr 14, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) South fish processing area; A relocatable power tap, affixed to overhead electrical conduit, was being used to supply power to two digital fish scales.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 G02 II

Other-than-serious 1 instance 2 exposed
Issued
Mar 17, 2020
Abate by
Apr 14, 2020
Penalty
Initial $325 · Current $163 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap:    (a) Herring processing area; A flexible extension cord used to supply power to a Dayton Model No. 6K791A electrical motor on a skinning machine conveyor was not used in a continuous length without a splice or tap.
Recent events (2)
  • · I (O) $163
  • · Z (O) $325

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344529797.