Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MINOVA USA INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MINOVA USA INC. in 101 VALLEY DR., SOUTH POINT, OH 45680 (NAICS 332722). OSHA activity number 344537725.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Minova USA INC. — free Get an email when a new federal OSHA severe-injury report for Minova USA INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MINOVA USA INC.
Site address
101 VALLEY DR.
City
SOUTH POINT
State
OH
ZIP
45680
Mailing
101 VALLEY DR., SOUTH POINT, OH 45680
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332722
Employees
65
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I A

Other-than-serious 1 instance 3 exposed
Issued
Jan 29, 2020
Abate by
Feb 25, 2020
Penalty
Initial $9,639 · Current $6,000 Reduced
29 CFR 1910.147(c)(7)(i)(A):     Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    The control of hazardous energy authorized employee training provided to machine operators was inadequate in that did it not address the recognition of hazardous energy sources and the means necessary for energy isolation and control that were required for the Threader machine during upset conditions.
Recent events (2)
  • — I (O) $6000
  • — Z (S) $9639

1910.147 D

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jan 29, 2020
Abate by
Mar 17, 2020
Penalty
Initial $13,494 · Current $0 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  Employees who perform servicing and maintenance activities on or around the Threader machine were not required to:  (1) Know the type and magnitude of the electrical, pneumatic and stored energy, the hazards of these energies to be controlled, and the method or means to control the energy. (2) Physically locate and operate energy isolating devices in such a manner as to isolate the machine from the energy source. (3) Affix lockout devices to the energy isolating device (4) Prior to starting work on machines that have been locked out, verify that isolation and deenergization of the machine have been accomplished.  Machine operators were exposed to a struck-by, caught inbetween hazard from the horizontal movement of the upper die bar on the Threader machine between the transfer table and upper die bar while an operator retrieved raised bars and bars on the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13494

View Minova USA INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344537725.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.