ARCADIA, WI —
OSHA Inspection: FRENCH CREEK CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FRENCH CREEK CONSTRUCTION LLC in 463 EAST MAIN STREET, ARCADIA, WI 54612 (NAICS 236115). OSHA activity number 344539036.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRENCH CREEK CONSTRUCTION LLC
- Site address
- 463 EAST MAIN STREET
- City
- ARCADIA
- State
- WI
- ZIP
- 54612
- Mailing
- N22982 LINRUDE ROAD, ETTRICK, WI 54627
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 A06
- Issued
- Jan 23, 2020
- Abate by
- Feb 13, 2020
- Penalty
- Initial $4,048 · Current $2,429 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person and were not constructed and loaded in accordance with that design: (a) 463 East Main Street Arcadia, WI; On or before January 6, 2020, employees were utilizing scaffold system(s) that presented hazards associated with scaffold design and construction, including, incomplete decking, missing mud sills, and inadequate fall protection.
Recent events (2)
- — I (S) $2429
- — Z (S) $4048
1926.451 B01
- Issued
- Jan 23, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: (a) 463 East Main Street Arcadia, WI; On or about January 6, 2020, a fabricated frame supported scaffold system, utilized to access the roof on the east side of a residential structure, was not fully planked or decked between the front uprights and the guardrail supports. (b) 463 East Main Street Arcadia, WI; On or about January 3, 2020, a fabricated frame supported scaffold system, utilized to perform roofing work on the west side of a residential structure, was not fully planked or decked between the front uprights and the guardrail supports.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Jan 23, 2020
- Abate by
- Feb 13, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: (a) 463 East Main Street Arcadia, WI; On or about January 6, 2020, a fabricated frame supported scaffold system, utilized to access the roof on the east side of a residential structure, did not bear on mud sills or other adequate firm foundation. (b) 463 East Main Street Arcadia, WI; On or about January 3, 2020, a fabricated frame supported scaffold system, utilized to perform roofing work on the west side of a residential structure, did not bear on mud sills or other adequate firm foundation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Jan 23, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: (a) 463 East Main Street Arcadia, WI; On or about January 3, 2020, an employee was performing work from an unprotected scaffold greater than 10 feet above ground without adequate fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Jan 23, 2020
- Penalty
- Initial $2,313 · Current $1,388 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet above the upper landing surface being accessed: (a) 463 East Main Street Arcadia, WI; On or about January 6, 2020, an extension ladder positioned on the east side of the residential structure for roof access did not extend at least 3 feet above the landing surface.
Recent events (2)
- — I (S) $1388
- — Z (S) $2313
More inspections in this industry (NAICS 236115)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344539036.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.