WASHINGTON, DC ·
OSHA Inspection: ONE SUN, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ONE SUN, LLC in 4212 EAST CAPTIOL ST., NE, WASHINGTON, DC 20019 (NAICS 238290). OSHA activity number 344540588.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ONE SUN, LLC
- Site address
- 4212 EAST CAPTIOL ST., NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20019
- Mailing
- 100 SUN AVE., NE, SUITE 650, ALBUQUERQUE, NM 87109
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238290
- Employees
- 7
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1926.501 B13
- Issued
- Jul 6, 2020
- Abate by
- Jul 23, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Roof, Building 37 - On or about January 6, 2020, workers installing solar panels on a 50 foot by 40 foot flat roof were exposed to a 30 foot fall and were not provided with personal fall protection, standard guard rails or nets. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- · Z (S) $4048
More inspections in this industry (NAICS 238290)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344540588.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.