Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: METAL PROCESSING INTERNATIONAL, L.P.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of METAL PROCESSING INTERNATIONAL, L.P. in 1108 BUSINESS PARK DRIVE, MISSION, TX 78572 (NAICS 332812). OSHA activity number 344544192.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Metal Processing International, L.P. — free Get an email when a new federal OSHA severe-injury report for Metal Processing International, L.P. is published. One employer, no account, unsubscribe in one click.
Site address
1108 BUSINESS PARK DRIVE
City
MISSION
State
TX
ZIP
78572
Mailing
1801 BOREN BLVD., SEMINOLE, OK 74868
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
54
Ownership type
A

5 citations on file for this inspection.

1910.106 D04

Other-than-serious 1 instance 1 exposed
Issued
Apr 3, 2020
Abate by
Apr 29, 2020
Penalty
Initial $8,096 · Current $0 Reduced
29 CFR 1910.106(d)(4)(i): Inside flammable or combustible liquid storage room(s) were not constructed to meet the required fire-resistive rating as specified in NFPA 251-1969:    On or about January 7, 2020 in the wet spray storage area/paint storage area, the employer stored flammable chemicals, such as but not limited to, acetone, paint activator, xylan black product, and isopropanol, in a chemical storage room that was not constructed to meet the required fire-resistive rating for its use.    An inside storage room for flammable liquids must also contain the following:    1.  Rating and capacity will comply with Table H-13;  2.  Electrical wiring and equipment located inside the storage room used for Category 1 or 2 flammable liquids or Category 3 with a flashpoint below 100 F (37.8 C) will be approved under subpart S of this part for Class 1, Division 2 hazardous locations;  3.  Ventilation system will be designed to provide for a complete change of air within the room at least six times per hour; and,  4.  Room will have at least one clear main aisle at least 3 feet wide with no stacking of containers over 30 gallons of capacity.
Recent events (2)
  • — I (O) $0
  • — Z (S) $8096

1910.147 C04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2020
Abate by
Apr 29, 2020
Penalty
Initial $6,747 · Current $6,747
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  On or about January 7, 2020 at this facility in ECoat 3, employees performed lock out to repair a motor to tank 1. The employer did not have specific written procedures for this type of equipment.
Recent events (2)
  • — I (S) $6747
  • — Z (S) $6747

1910.146 C01

Other-than-serious 25 instances 1 exposed
Issued
Apr 3, 2020
Abate by
Apr 29, 2020
Penalty
Initial $757 · Current $0 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    At this facility, the employer did not adequately evaluate the facility to determine all potential permit-required confined spaces, such as but not limited to, electrocoating tanks.
Recent events (2)
  • — I (O) $0
  • — Z (O) $757

1910.157 C01

Deleted Other-than-serious 3 instances 5 exposed
Issued
Apr 3, 2020
Penalty
Initial $757 · Current $0 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  The employer did not mount or identify the location of fire extinguishers throughout the facility, such as but not limited to, the Ecoat 3 area, office area leading to production, and wet spray room/flammable storage area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $757

1910.178 L01 II

Deleted Other-than-serious 1 instance 1 exposed
Issued
Apr 3, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck:  On or about January 7, 2020, an employee operated a forklift and had not completed forklift training.