WASHINGTON, DC ·
OSHA Inspection: WRR MASONRY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WRR MASONRY LLC in 3113 ARIZONA AVE, WASHINGTON, DC 20016 (NAICS 238140). OSHA activity number 344545538.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WRR MASONRY LLC
- Site address
- 3113 ARIZONA AVE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 9049 REYNOLDS PLACE, MANASSAS, VA 20110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.100 A
- Issued
- Jul 6, 2020
- Abate by
- Jul 10, 2020
- Penalty
- Initial $4,453 · Current $4,453
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about January 8, 2020; front of residential site; employees adjacent to the scaffold and/or the hoist area were not wearing a hard hat to protect them from falling objects that included but was not limited to bricks . In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- · Z (S) $4453
1926.451 B01
- Issued
- Jul 6, 2020
- Abate by
- Jul 10, 2020
- Penalty
- Initial $4,453 · Current $4,453
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights a) On or about January 8, 2020; front of residential site; the working platforms of the fourth level of the scaffold system was not fully planked exposing employees to a fall hazard of approximately 27 feet while performing masonry operations. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- · Z (S) $4453
1926.451 G01 VII
- Issued
- Jul 6, 2020
- Abate by
- Jul 10, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) On or about January 8, 2020, front area; employees were exposed to a fall hazard of approximately 18 feet while using an unguarded scaffold grade plank that was placed between two sections of the scaffolding components to connect the scaffolds that had been erected. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- · Z (S) $0
1926.451 G04 III
- Issued
- Jul 6, 2020
- Abate by
- Jul 10, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(iii): When midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent structural members are used, they were not installed between the top edge of the guardrail system and the scaffold platform. a) On or about January 8, 2020; front of residential site; the scaffold system erected at the location by the employer had missing mid-rails along the working platforms exposing the employees to an estimated 27-foot fall hazard while hoisting materials to the platform. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- · Z (S) $0
1926.451 H02 II
- Issued
- Jul 6, 2020
- Abate by
- Jul 10, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: a) On or about January 8, 2020; front of residential site; working platforms of the scaffold system had no toe-boards to prevent masonry tools or materials from falling and striking the employee working at ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- · Z (S) $0
1926.451 C01 II
- Issued
- Jul 6, 2020
- Abate by
- Jul 10, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide. a) On or about January 8, 2020; front area; employees were working on a scaffold system (5-tiers or 27-feet) which was not secured to prevent displacement while installing the brick veneer. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- · Z (S) $0
1926.454 A
- Issued
- Jul 6, 2020
- Abate by
- Jul 10, 2020
- Penalty
- Initial $4,453 · Current $4,453
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) On or about January 8, 2020; employees were not trained in the recognition of the potential hazards such as but not limited to fall and struck hazards that they were exposed to while working on or near the scaffold system. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- · Z (S) $4453
More inspections at WRR Masonry LLC
View WRR Masonry LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344545538.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.