Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NEWNAN WINDOW COMPANY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NEWNAN WINDOW COMPANY, LLC in BUILDING #5 104 ROLLING HILLS DRIVE, NEWNAN, GA 30263 (NAICS 238170). OSHA activity number 344546767.

Watch Newnan Window Company, LLC — free Get an email when a new federal OSHA severe-injury report for Newnan Window Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING #5 104 ROLLING HILLS DRIVE
City
NEWNAN
State
GA
ZIP
30263
Mailing
339 MILLARD FARMER INDUSTRIAL BLVD. SUITE 8-B, NEWNAN, GA 30263
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.451 G01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2892.00 · Current $1735.00 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:  (a) Apartment Building #5 located at 104 Rolling Hills Drive, West gable side: On or about 01/08/2020, and at times prior, the employer exposed employees to fall hazards of up to 15-feet, 6-inches to the lower level, in that a fall protection system was not provided to employees using a ladder jack scaffold plank engaged in vinyl siding activities.
Recent events (2)
  • — I (S) $1735.2
  • — Z (S) $2892

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:  (a) Apartment Building #5 located at 104 Rolling Hills Drive, West gable side and lower roof: On or about 01/08/2020, and at times prior, the employer exposed employees to fall hazards of up to 7-feet, 10-inches to the lower level, in that a fall protection system was not provided to employees engaged in siding work using the 6/12 pitched roof as a walking/working surface to access the ladder jack scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344546767.