PLAIN CITY, OH ·
OSHA Inspection: MAHAAN, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MAHAAN, LLC in 216 WEST BIGELOW AVENUE, PLAIN CITY, OH 43064 (NAICS 332710). OSHA activity number 344549217.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAHAAN, LLC
- Site address
- 216 WEST BIGELOW AVENUE
- City
- PLAIN CITY
- State
- OH
- ZIP
- 43064
- Mailing
- 216 WEST BIGELOW AVENUE, PLAIN CITY, OH 43064
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 3
- Ownership type
- Private (A)
Citations
16 citations on file for this inspection.
1910.22 A03
- Issued
- Feb 12, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $1,735 · Current $868 Reduced
General-duty citation text
29 CFR 1910.22(a)(3): (3) Walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice. a. On or about January 8, 2020, in the rear of the facility, coolant had been spilled on the floor, exposing employees to slip hazards.
Recent events (2)
- · I (S) $867.5
- · Z (S) $1735
1910.37 B06
- Issued
- Feb 12, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $1,735 · Current $868 Reduced
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2) are permitted. a. On or about January 8, 2020, the exit sign that was located above the exit door in the rear production area of the facility was not illuminated. b. a. On or about January 8, 2020, the exit sign that was located above the exit door near the restrooms was not illuminated. c. a. On or about January 8, 2020, the exit sign that was located above the exit door in the front production area of the facility was not illuminated.
Recent events (2)
- · I (S) $867.5
- · Z (S) $1735
1910.178 L01 I
- Issued
- Feb 12, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $2,313 · Current $1,157 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). a. On or about January 8, 2020, the employer did not provide forklift training for each employee who was authorized to operate a forklift.
Recent events (2)
- · I (S) $1156.5
- · Z (S) $2313
1910.178 Q07
- Issued
- Feb 12, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected. a. On or about January 8, 2020, the employer did not ensure that each forklift was inspected daily prior to being placed in service.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Feb 12, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $2,892 · Current $1,446 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a. On or about January 8, 2020, in the front production area, the rotating chuck on the Cutmaster Lathe (Model #DCL-2080) was not guarded to protect employees from flying chips.
Recent events (2)
- · I (S) $1446
- · Z (S) $2892
1910.215 A04
- Issued
- Feb 12, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $2,313 · Current $1,157 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion. a. On or about January 8, 2020, in the work area near the restrooms, work rests on two bench grinders were not used to support the work, which exposed employees to wheel breakage hazards.
Recent events (2)
- · I (S) $1156.5
- · Z (S) $2313
1910.219 D01
- Issued
- Feb 12, 2020
- Abate by
- Mar 3, 2020
- Penalty
- Initial $3,470 · Current $1,735 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes. a. On or about January 8, 2020, in the front production area of the facility, in-going nip points on the belt and pulley of the belt sander were not guarded.
Recent events (2)
- · I (S) $1735
- · Z (S) $3470
1910.219 F03
- Issued
- Feb 12, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets. a. On or about January 8, 2020, in the front production area of the facility, the chain and sprocket located on the Mazak Quick Turn 10 Universal was not guarded.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 F02
- Issued
- Feb 12, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $2,892 · Current $1,446 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident: a. On or about January 8, 2020, located in the work area near the restrooms, there were multiple electrical disconnects that were not marked to indicate the purpose of each one, thereby exposing the employees to the hazards associated with the equipment supplied disconnects.
Recent events (2)
- · I (S) $1446
- · Z (S) $2892
1910.303 G01 II
- Issued
- Feb 12, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded: a. On or about January 8, 2020, located in work area near the restrooms, materials such as boxes, unused equipment, and buckets of supplies were stored directly in front of the electrical disconnects, which restricted access to the controls in the event of an emergency.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 E01 II
- Issued
- Feb 12, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
1910.303(e)(1) Identification of manufacturer and ratings. Electric equipment may not be used unless the following markings have been placed on the equipment: 29 CFR 1910.303(e)(1)(ii): Other markings giving voltage, current, wattage, or other ratings as necessary. a. On or about January 8, 2020, the electrical disconnects located in the work area near the restrooms were not marked to indicate the voltage of the electrical equipment.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 D02
- Issued
- Feb 12, 2020
- Abate by
- Feb 25, 2020
- Penalty
- Initial $4,048 · Current $2,024 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. a. On or about January 8, 2020, the electrical breaker box located in the Speakman building which was used to control the lights in the building, did not have a dead front cover over the board.
Recent events (2)
- · I (S) $2024
- · Z (S) $4048
1910.1200 E01
- Issued
- Feb 12, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $1,735 · Current $868 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: a. On or about January 8, 2020, the employer did not develop and implement a written hazard communication program for employee exposure to chemicals such as, but not limited to, coolant and acetone.
Recent events (2)
- · I (S) $867.5
- · Z (S) $1735
1910.1200 G01
- Issued
- Feb 12, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use. a. On or about January 8, 2020, the employer did not obtain a safety data sheet for each hazardous chemical in the workplace such as, but not limited to, coolant and acetone.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 H01
- Issued
- Feb 12, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets. a. On or about January 8, 2020, the employer did not develop and implement a hazard communication training program for employee exposure to chemicals such as, but not limited to, coolant and acetone.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.38 A
- Issued
- Feb 12, 2020
- Abate by
- Mar 19, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(a): Application. An employer must have an emergency action plan whenever an OSHA standard in this part requires one. The requirements in this section apply to each such emergency action plan. a. On or about January 8, 2020, the employer did not develop and implement an emergency action plan.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 332710)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344549217.