BROOKLYN, NY ·
OSHA Inspection: ALL CITY CONSTRUCTION NY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALL CITY CONSTRUCTION NY INC. in 1437 74TH ST., BROOKLYN, NY 11228 (NAICS 236118). OSHA activity number 344549381.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL CITY CONSTRUCTION NY INC.
- Site address
- 1437 74TH ST.
- City
- BROOKLYN
- State
- NY
- ZIP
- 11228
- Mailing
- 275 BROOME ST. APT 4, NEW YORK, NY 10002
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.300 B01
- Issued
- Apr 9, 2020
- Penalty
- Initial $3,856 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) 1st floor, bathroom: An employee used an electric powered angle grinder to cut plastic strips for shower installation. The angle grinder was designed to accommodate a guard for the cutting wheel, and was not equipped with such guard when in use. On or about 01/08/2020.
Recent events (2)
- · I (S) $2100
- · Z (S) $3856
1926.404 B01 I
- Issued
- Apr 9, 2020
- Penalty
- Initial $3,856 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) 1st floor: An employee used electric powered tools to do framing installation. The tools were connected to extension cords, which were routed to nearby outlet devices and were not provided with ground fault circuit interrupter. On or about 01/08/2020.
Recent events (2)
- · I (S) $2100
- · Z (S) $3856
1926.405 J01 II
- Issued
- Apr 9, 2020
- Penalty
- Initial $3,856 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported. a) Throughout entire site, 1st and 2nd floor: Energized electrical receptacles and light switches were not securely supported. They were left hanging by energized wires attached to the devices. On or about 01/08/2020.
Recent events (2)
- · I (S) $2100
- · Z (S) $3856
1926.501 B13
- Issued
- Apr 9, 2020
- Penalty
- Initial $5,398 · Current $3,700 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. a) 2nd floor balcony: An employee was working at the edge of the 2nd floor balcony without fall protection. He was exposed to falling approximately 12 feet to ground. On or about 01/08/2020.
Recent events (2)
- · I (S) $3700
- · Z (S) $5398
More inspections in this industry (NAICS 236118)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344549381.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.