Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARINE CORPS COMMUNITY SERVICES - DESERT WINDS GOLF COURSE in BUILDING 2316 MCAGCC 29 PALMS, TWENTYNINE PALMS MCB, CA 92278 (NAICS 713910). OSHA activity number 344551080.

Watch Marine Corps Community Services - Desert Winds Golf Course — free Get an email when a new federal OSHA severe-injury report for Marine Corps Community Services - Desert Winds Golf Course is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 2316 MCAGCC 29 PALMS
City
TWENTYNINE PALMS MCB
State
CA
ZIP
92278
Mailing
MCCS DIRECTORATE BLDG 1522 MCAGCC BOX 788150, TWENTYNINE PALMS MCB, CA 92278
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713910
Employees
8
Ownership type
D

10 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  Building 2316: Employees perform maintenance and/or cleaning operations on equipment, including but not limited to the Foley United ACCU-Master grinder. Training on the energy control program has not been provided to employees at the authorized and affected level, exposing employees to the unintentional release of hazardous energy.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Diesel fuel outdoor storage tank: The Ansul Sentry ABC portable fire extinguisher was stored outside on the concrete and weathered. The extinguisher was not mounted to protect it from damage from the environmental conditions. Employees were exposed to fire hazards while filling lawn mowing equipment with diesel fuel without an extinguisher mounted and available for use.
Recent events (1)
  • — Z (S) $0

1910.157 E03

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): The date of the annual maintenance check of portable fire extinguishers was not recorded:  Diesel fuel outdoor storage tank: Records of the most recent annual maintenance check for the Ansul Sentry portable fire extinguisher were unavailable at the time of the inspection. Employees were exposed to fire hazards while filling lawn mowing equipment with diesel fuel and not having an annually-serviced extinguisher available.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  Building 2316 Workshop: The Rockwell bench grinder, used for metal fabrication operations, had a work rest that measured 1/2 inches from the abrasive wheel. Employees were exposed to entanglement hazards when grinding on lawn mowing and golf cart equipment.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  Building 2316 Workshop: The Rockwell bench grinder, used for metal fabrication operations, had a tongue guard that measured 3/4 inches from the abrasive wheel. Employees were exposed to struck-by hazards when grinding on lawn mowing and golf cart equipment.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Building 2316 Workshop: The Magic Chef microwave and toaster, used for employee breaks, was plugged into a relocatable power tap. Employees were exposed to fire and/or electrical shock hazards from using electrical equipment improperly.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Building 2316 Workshop: A metallic outlet box that had energized parts exposed was used to power a relocatable power tap, microwave, and toaster. Employees were exposed to electrical shock hazards when using unguarded electrical equipment.
Recent events (1)
  • — Z (S) $0

1910.141 A03 I

Other-than-serious 1 instance 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed:  Building 2316 Workshop: The Magic Chef microwave, used for employee breaks, was not maintained in a clean and sanitary condition. Food product and spatter coated the inside of the microwave. Employees were exposed to bacteria and/or sanitation hazards from using an unclean microwave.
Recent events (1)
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords were being used as a permanent source for wiring:  Building 2316 Workshop: Employees were using an orange flexible cord to power a Black & Decker coffee maker. The flexible cable was being used as the primary source of power in lieu of permanent wiring.
Recent events (1)
  • — Z (O) $0

1910.1200 G08

Other-than-serious 3 instances 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical:  Building 2316: Employees perform turf treatment and maintenance operations for the golf course. The following chemicals used for the turf were maintained onsite without a safety data sheet:  a) Black Gypsum b) Aqueduct Flex c) Assure 5-5-5 Employees were exposed to respiratory and/or skin irritation hazards.
Recent events (1)
  • — Z (O) $0