Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CADOTT GRAIN SERVICE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CADOTT GRAIN SERVICE, LLC in 22939 COUNTY HWY X, CADOTT, WI 54727 (NAICS 424510). OSHA activity number 344552450.

Watch Cadott Grain Service, LLC — free Get an email when a new federal OSHA severe-injury report for Cadott Grain Service, LLC is published. One employer, no account, unsubscribe in one click.
Site address
22939 COUNTY HWY X
City
CADOTT
State
WI
ZIP
54727
Mailing
P.O. BOX 63, CADOTT, WI 54727
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
7
Ownership type
A

4 citations on file for this inspection.

1910.67 C02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2892.00 · Current $2024.00 Reduced
29 CFR 1910.67(c)(2)(ii): An employee(s) operating an aerial lift(s) was not properly trained:    (a) Throughout the grain site; Employees did not receive operator training before being allowed to operate an extensible aerial lift.
Recent events (2)
  • — I (S) $2024.4
  • — Z (S) $2892

1910.67 C02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.67(c)(2)(v): (v) A personal fall arrest or travel restraint system that meets the requirements in 29 CFR 1910, subpart I, was not worn and attached to the boom or basket when working from an aerial lift:  (a) Throughout the grain site; Personal fall arrest systems were not worn and attached to designated anchorage points on an extensible aerial lift while employees performed work from inside the basket.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.110 C05 I I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2313.00 · Current $1620.00 Reduced
29 CFR 1910.110(c)(5)(i)(i): Containers, regulating equipment, manifolds, pipe, tubing, and hose were not located so as to minimize exposure to abnormally high temperatures (such as may result from exposure to convection or radiation from heating equipment or installation in confined spaces), physical damage, or tampering by unauthorized persons:    (a) Near soybean dryer; Two, 1000 pound liquid propane tanks were not protected from physical damage.
Recent events (2)
  • — I (S) $1619.6
  • — Z (S) $2313

1910.272 D

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.272(d): The employer did not develop and implement an emergency action plan meeting the requirements contained in 1910.38:  (a) Throughout the facility; An emergency action plan was not developed and implemented to ensure that employees would be informed of the mandatory requirements set forth by 29 CFR 1910.38(a through f) for fire or other emergency situations.