Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: FIESTA MART, L.L.C.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FIESTA MART, L.L.C. in 11006 AIRLINE DRIVE, HOUSTON, TX 77037 (NAICS 445110). OSHA activity number 344556170.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fiesta Mart, L.L.C. for free Get an email when a new federal OSHA severe-injury report for Fiesta Mart, L.L.C. is published. One employer, no account, unsubscribe in one click.
Establishment
FIESTA MART, L.L.C.
Site address
11006 AIRLINE DRIVE
City
HOUSTON
State
TX
ZIP
77037
Mailing
5444 WESTHEIMER ROAD SUITE 101, HOUSTON, TX 77056
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445110
Employees
120
Ownership type
Private (A)

3 citations on file for this inspection.

1910.212 A03 II

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jan 30, 2020
Abate by
Feb 5, 2020
Penalty
Initial $12,145 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s).  On or about January 10, 2020 and at times prior thereto, where a butcher was exposed to an amputation hazard by placing their hands near the point of operation while operating a Biro meat cutting saw.
Recent events (2)
  • · I (S) $0
  • · Z (S) $12145

1910.303 B02

Other-than-serious 1 instance 13 exposed
Issued
Jan 30, 2020
Abate by
Feb 5, 2020
Penalty
Initial $7,374 · Current $5,161 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.    On or about January 14, 2020, in the meat department, where employees were exposed to electrical and fire hazards while using an electrical box as a power supply that was not installed in accordance with its listing and labeling instructions.
Recent events (2)
  • · I (O) $5161
  • · Z (S) $7374

1910.305 G01 IV B

Other-than-serious 3 instances 13 exposed
Issued
Jan 30, 2020
Abate by
Feb 26, 2020
Penalty
Initial $4,425 · Current $3,097 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors.    a. On or about January 14, 2020, in the middle of the meat department, employees were exposed to an electrical hazard when a flexible cord used to power a Biro meat saw ran through a hole in the ceiling.    b. On or about January 14, 2020, in the corner of the meat department, employees were exposed to an electrical hazard when a flexible cord used to power a Biro meat saw ran through a hole in the ceiling.    c. On or about January 14, 2020, employees were exposed to an electrical hazard when a flexible cord used to power an Autolabeler ran through a hole in the ceiling.
Recent events (2)
  • · I (O) $3097
  • · Z (S) $4425

View Fiesta Mart, L.L.C.'s full OSHA safety record →