WINONA, TX —
OSHA Inspection: AMERICAN MIDSTREAM GAS SOLUTIONS, LP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN MIDSTREAM GAS SOLUTIONS, LP in 4426 FM 757, WINONA, TX 75792 (NAICS 211112). OSHA activity number 344556329.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN MIDSTREAM GAS SOLUTIONS, LP
- Site address
- 4426 FM 757
- City
- WINONA
- State
- TX
- ZIP
- 75792
- Mailing
- 3407 CAMP SWITCH ROAD, LONGVIEW, TX 75604
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 211112
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.119 D03 I D
- Issued
- Jun 26, 2020
- Abate by
- Jul 16, 2020
- Penalty
- Initial $10,930 · Current $8,100 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(D): Process safety information (PSI) pertaining to the equipment in the process did not include relief system design and design basis: a) On or about January 13, 2020, the employer did not ensure that PSI for pressure relief valves included the relief system design and design basis in the covered process for Deethanizer PSV-1100. b) On or about January 13, 2020, the employer did not ensure that PSI for pressure relief valves included the relief system design and design basis in the covered process for Propane Tank PSV-062. c) On or about January 13, 2020, the employer did not ensure that PSI for pressure relief valves included the relief system design and design basis in the covered process for Butane Tank PSV-068. d) On or about January 13, 2020, the employer did not ensure that PSI for pressure relief valves included the relief system design and design basis in the covered process for Regeneration Gas Heater PSV-750.
Recent events (2)
- — I (S) $8100
- — Z (S) $10930
1910.119 D03 II
- Issued
- Jun 26, 2020
- Abate by
- Jul 16, 2020
- Penalty
- Initial $7,808 · Current $5,808 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. On or about January 13, 2020, the employer did not document that equipment, including the Butane tank V-068 complied with the employers chosen recognized and generally accepted good engineering practice (RAGAGEP), American Petroleum Institute (API) 510, when the employer failed to maintain construction and design information.
Recent events (2)
- — I (S) $5808
- — Z (S) $7808
1910.119 F03
- Issued
- Jun 26, 2020
- Abate by
- Jul 16, 2020
- Penalty
- Initial $4,684 · Current $3,184 Reduced
General-duty citation text
29 CFR 1910.119(f)(3): The employer did not annually certify that operating procedures were current and accurate. On or about January 13, 2020, the employer did not annually certify that operating procedures were current and accurate.
Recent events (2)
- — I (S) $3184
- — Z (S) $4684
1910.119 F04
- Issued
- Jun 26, 2020
- Abate by
- Jul 16, 2020
- Penalty
- Initial $7,808 · Current $5,808 Reduced
General-duty citation text
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel: On or about January 13, 2020, the employer failed to ensure its employees followed the safety work practices to provide for the control of entrance into a facility by employees, contractor employees, and other support personnel in the Chapel Hill Gas Plant.
Recent events (2)
- — I (S) $5808
- — Z (S) $7808
1910.119 G02
- Issued
- Jun 26, 2020
- Abate by
- Jul 16, 2020
- Penalty
- Initial $4,684 · Current $3,184 Reduced
General-duty citation text
29 CFR 1910.119(g)(2): Refresher training was not provided at least every three years to each employee involved in operating a process to assure that the employee understands and adheres to the current operating procedures of the process: On or about January 13, 2020, the employer failed to provide refresher training at least every three years to each employee involved in operating a process to assure the employee understands and adheres to the current operating procedures of the process.
Recent events (2)
- — I (S) $3184
- — Z (S) $4684
1910.119 J02
- Issued
- Jun 26, 2020
- Abate by
- Jul 16, 2020
- Penalty
- Initial $10,930 · Current $8,830 Reduced
General-duty citation text
29 CFR 1910.9(j)(2): The employer did not establish and implement written procedures to maintain the on-going integrity of process equipment. a) On or about January 13, 2020, the employer did not implement written procedures for testing or inspecting for the following process equipment that including, but not limited to: 1. Deethanizer PSV-1100, 2. Propane Tank PSV-062, 3. Butane Tank PSV-068, 4. Regeneration Gas Heater PSV-750, b) On or about January 13, 2020, the employer did not implement written procedures for testing or inspecting for the following process equipment that including, but not limited to: 1. Deethanizer LAL-1100, 2. Deethanizer LSL-1100, 3. Deethanizer LAH-1100, 4. Deporpanizer LAL-1400 5. Deporpanizer LAH-1400 6. Debutanizer LAH-1500, 7. Debutanizer LAL-1500, c) On or about January 13, 2020, the employer did not implement written procedures for testing or inspecting for the following process equipment that including but not limited to Heaters Burner Control DA 750. d) On or about January 13, 2020, the employer did not implement written procedures for testing or inspecting for the following process equipment that including, but not limited to emergency Shutdown Button(s).
Recent events (2)
- — I (S) $8830
- — Z (S) $10930
1910.119 J04 I
- Issued
- Jun 26, 2020
- Abate by
- Jul 16, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment a) On or about January 13, 2020, the employer did not perform inspections and testing on process equipment, including pressure relief valves such as, but not limited to: 1. Deethanizer PSV-1100, 2. Propane Tank PSV-062, 3. Butane Tank PSV-068, 4. Regeneration Gas Heater PSV-750, b) On or about January 13, 2020, the employer did not perform inspections and testing on process equipment, including vessel alarms such as, but not limited to: 1. Deethanizer LAL-1100, 2. Deethanizer LSL-1100, 3. Deethanizer LAH-1100, 4. Deporpanizer LAL-1400 5. Deporpanizer LAH-1400 6. Debutanizer LAH-1500, 7. Debutanizer LAL-1500, c) On or about January 13, 2020, the employer did not perform inspections and testing on process equipment, including process equipment such as, but not limited to Heaters Burner Control DA 750. d) On or about January 13, 2020, the employer did not perform inspections and testing on process equipment, including process equipment such as, but not limited to emergency Shutdown Button(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 H02 V
- Issued
- Jun 26, 2020
- Abate by
- Jul 16, 2020
- Penalty
- Initial $876 · Current $876
General-duty citation text
29 CFR 1910.119(h)(2)(v): The employer did not periodically evaluate the performance of contract employers to ensure they are fulfilling their obligations as specified in 29 CFR 1910.119(h)(3). On or about January 13, 2020, the employer did not periodically evaluate the performance of contract employer Genesis Endeavors in fulfilling their obligations as specified in paragraph (h)(3).
Recent events (2)
- — I (O) $876
- — Z (O) $876
More inspections in this industry (NAICS 211112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344556329.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.