Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,547Inspections Most recent open 2026-09-01 Last loaded 2026-09-04

OSHA Inspection: CORDOS DEVELOPMENT & ASSOCIATES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CORDOS DEVELOPMENT & ASSOCIATES, LLC in 2308 W CULLOM AVE, CHICAGO, IL 60618 (NAICS 236118). OSHA activity number 344560859.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cordos Development & Associates, LLC for free Get an email when a new federal OSHA severe-injury report for Cordos Development & Associates, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2308 W CULLOM AVE
City
CHICAGO
State
IL
ZIP
60618
Mailing
10 W HUBBARD ST STE 2B, CHICAGO, IL 60654
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

1926.1052 C01 II

Serious Gravity 1 1 instance 5 exposed
Issued
Feb 5, 2020
Penalty
Initial $2,313 · Current $1,619 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one stairrail system along each unprotected side or edge:  a)  On January 15, 2020, employees were accessing the upper floors of the building by way of stairways that did not have a stairrail system along the unprotected side.  No abatement certification or documentation is required for this item.
Recent events (2)
  • · I (S) $1619.1
  • · Z (S) $2313

1926.404 B01 I

Other-than-serious 1 instance 5 exposed
Issued
Feb 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(i):  The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    a)  On January 15, 2020, employees were provided with electrical tools and equipment connected by cord and plug without the use of an assured equipment grounding conductor program or ground fault circuit interrupters (GFCI's).    No abatement certification or documentation is required for this item.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344560859.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.