EAST GLASTONBURY, CT —
OSHA Inspection: QUALITY NAME PLATE, INCORPORATED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of QUALITY NAME PLATE, INCORPORATED in 22 FISHER HILL ROAD, EAST GLASTONBURY, CT 06025 (NAICS 332322). OSHA activity number 344564091.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUALITY NAME PLATE, INCORPORATED
- Site address
- 22 FISHER HILL ROAD
- City
- EAST GLASTONBURY
- State
- CT
- ZIP
- 06025
- Mailing
- P.O. BOX 68, EAST GLASTONBURY, CT 06025
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 60
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.106 D02 III
- Issued
- Feb 24, 2020
- Penalty
- Initial $4,048 · Current $2,024 Reduced
General-duty citation text
29 CFR 1910.106(d)(2)(iii): Flammable liquid containers were not in accordance with table H-12: Datron Room: On, or about, January 15, 2020, ethyl alcohol, a Category 2 flammable liquid with a flashpoint of 55 degrees F, was dispensed into plastic five-gallon containers for use at each of the two Datron machines. Table H-12 of the standard limits the size of plastic secondary containers to one quart.
Recent events (2)
- — I (S) $2024
- — Z (S) $4048
1910.106 E06 I
- Issued
- Feb 24, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: Datron Room: On, or about, January 15, 2020, two five-gallon containers of ethyl alcohol, a Category 2 flammable liquid with a flashpoint of 55 degrees F, were not grounded to the building structure. The solvent was being dispensed out of plastic containers that cannot be grounded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C
- Issued
- Feb 24, 2020
- Abate by
- Apr 9, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: Datron Room: On, or about, January 15, 2020, the cabinet exhaust fan provided on each of the Datron machines was not rated for use with flammable vapors.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Feb 24, 2020
- Abate by
- Apr 9, 2020
- Penalty
- Initial $5,060 · Current $2,530 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Machine Department: On, or about, January 15, 2020, adequate safeguarding had not been provided on the following shears: A. Niagara 1R-4-10Ga: Round guards provided for the hold-downs were at varying heights. The fifth hold-down from the left exceeded one quarter of an inch above the bed of the shear. B. Pexto: A gap was left between the machine frame and guard that allowed access to the blade by reaching behind the guard. C. Niagara, two foot shear: A gap was left between the machine frame and guard to allowed access to the blade by reaching behind the guard. D. Niagara three foot shear: The barrier guard provided on this shear had bowed up in the middle, allowing access to the shear point.
Recent events (2)
- — I (S) $2530
- — Z (S) $5060
1910.217 B12
- Issued
- Feb 24, 2020
- Abate by
- Apr 9, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(12): All pressure vessels used in conjunction with power presses did not conform to the American Society of Mechanical Engineers Code for Pressure Vessels, 1968 Edition: Machine Department: On, or about, January 15, 2020, air tanks provided on the following partial revolution mechanical power presses had not been provided with pressure relief valves: A. Press #19, V&O. B. Press #3, Minster. C. Press #13, Federal.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Quality Name Plate, Incorporated
View Quality Name Plate, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344564091.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.