Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FAA FLIGHT STANDARDS DISTRICT OFFICE-63

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FAA FLIGHT STANDARDS DISTRICT OFFICE-63 in 525 FD ROOSEVELT AVE SUITE 901, SAN JUAN, PR 00918 (NAICS 926120). OSHA activity number 344564315.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch FAA Flight Standards District Office-63 — free Get an email when a new federal OSHA severe-injury report for FAA Flight Standards District Office-63 is published. One employer, no account, unsubscribe in one click.
Site address
525 FD ROOSEVELT AVE SUITE 901
City
SAN JUAN
State
PR
ZIP
00918
Mailing
525 FD ROOSEVELT AVE SUITE 901, SAN JUAN, PR 00918
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
926120
Employees
23
Ownership type
D

1 citation on file for this inspection.

1910.303 G01

Serious Gravity 5 3 instances 23 exposed
Issued
Apr 15, 2020
Abate by
May 6, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.  a. On or about January 15, 2020, in the Security System Room of the FAA Flight Standards District Office - 63 at 525 FD Roosevelt Avenue, Suite 901, San Juan, PR;  two (2) electrical service panels were not readily accessible.  b. On or about January 15, 2020, in the LAN/Servers Room of the FAA Flight Standards District Office - 63 at 525 FD Roosevelt Avenue, Suite 901, San Juan, PR;  one (1) electrical service panel was not readily accessible.  NOTES:  1. Certification of abatement is not required for instance a. as abatement was witnessed by the compliance safety and health officer during the inspection. 2. Certification and documentation of abatement must be submitted for instance b. as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (1)
  • — Z (S) $0

View FAA Flight Standards District Office-63's full OSHA safety record →