GREENVILLE, WI —
OSHA Inspection: F.C. DADSON, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of F.C. DADSON, LLC in N1043 CRAFTSMEN DRIVE, GREENVILLE, WI 54942 (NAICS 337215). OSHA activity number 344568720.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- F.C. DADSON, LLC
- Site address
- N1043 CRAFTSMEN DRIVE
- City
- GREENVILLE
- State
- WI
- ZIP
- 54942
- Mailing
- N1043 CRAFTSMEN DRIVE, GREENVILLE, WI 54942
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337215
- Employees
- 60
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.107 C06
- Issued
- Apr 17, 2020
- Abate by
- Aug 31, 2020
- Penalty
- Initial $5,735 · Current $2,868 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations: a) On or about January 21, 2020, employees were spraying Wilsonart 950 (Red) Contact Adhesive which is a Category 2 Flammable Liquid in an area with general electrical service.
Recent events (2)
- — I (S) $2867.5
- — Z (S) $5735
1910.213 C02
- Issued
- Apr 17, 2020
- Penalty
- Initial $4,588 · Current $2,294 Reduced
General-duty citation text
29 CFR 1910.213(c)(2): Each hand-fed circular ripsaw shall be furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf. It shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position. The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted. The provision of a spreader in connection with grooving, dadoing, or rabbeting is not required. On the completion of such operations, the spreader shall be immediately replaced: a) On January 21, 2020, an Assembler was cutting laminate on the Delta Rockwell 10" Unisaw without the spreader in place.
Recent events (2)
- — I (S) $2294
- — Z (S) $4588
1910.213 C03
- Issued
- Apr 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Each hand-fed circular ripsaw shall be provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of materials being cut. a) On January 21, 2020, an Assembler was cutting laminate on the Delta Rockwell 10" Unisaw without the nonkickback fingers or dogs in place.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K06
- Issued
- Apr 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The basic advisory information on respirators, as presented in Appendix D of this section, shall be provided by the employer in any written or oral format, to employees who wear respirators when such use is not required by this section or by the employer. a) On or about January 21, 2020, employees voluntarily using filtering facepiece (dust masks), like the 3M #8210 N95 Particulate Respirators available on-site, had not received training on the contents of 29 CFR 1910.134 Appendix D.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L06
- Issued
- Apr 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: a) On or about January 21, 2020, the employer had not documented the 3 year refresher forklift operator evaluations.