WASHINGTON, DC ·
OSHA Inspection: R & G MASTER FLOORS, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of R & G MASTER FLOORS, LLC in 721 KENNEDY ST., NW, WASHINGTON, DC 20006 (NAICS 238330). OSHA activity number 344570452.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R & G MASTER FLOORS, LLC
- Site address
- 721 KENNEDY ST., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20006
- Mailing
- 14005 EAGLE CT., ROCKVILLE, MD 20853
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238330
- Employees
- 4
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.304 F
- Issued
- Jul 16, 2020
- Abate by
- Aug 4, 2020
- Penalty
- Initial $2,458 · Current $2,458
General-duty citation text
29 CFR 1926.304(f): Section 4.1.2(a) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not guarded by an automatically adjusting hood which completely enclosed: (a) Fourth Floor, Unit 8 - On or about January 16, 2020, flooring mechanics were using a DeWalt 10 inch portable table saw (serial no. 2013-11-CT-225972) to rip 1 X 8 X 3/8 inch flooring lumber while the saw's rotating blade was not protected by a hood or similar suitable guarding. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- · Z (S) $2458
1926.304 F
- Issued
- Jul 16, 2020
- Abate by
- Aug 5, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(f): Section 4.1.9(c) American National Standards Institute 01.1-1961, Safety code for /Woodworking Machinery as adopted by 29 CFR 1926.304(f): Radial saw(s) used for ripping were not provided with nonkickback fingers or dogs: (a) Fourth Floor, Unit 8 - On or about June 16, 2020, flooring mechanics were using a DeWalt 10 inch portable table saw (serial no. 2013-11-CT-225972) to rip 1 X 8 X 3/8 inch flooring lumber while the saw was not provided with nonkickback fingers or dogs. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 238330)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344570452.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.