Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUN LABS GROUP LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of SUN LABS GROUP LLC in 5114 THIRD AVE, BROOKLYN, NY 11220 (NAICS 325611). OSHA activity number 344575584.

Watch SUN Labs Group LLC — free Get an email when a new federal OSHA severe-injury report for SUN Labs Group LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SUN LABS GROUP LLC
Site address
5114 THIRD AVE
City
BROOKLYN
State
NY
ZIP
11220
Mailing
5114 THIRD AVE, BROOKLYN, NY 11220
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325611
Employees
15
Ownership type
A

6 citations on file for this inspection.

1910.23 E01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3856.00 · Current $1986.00 Reduced
29 CFR 1910.23(e)(1)(ii): The steps and platforms of mobile ladder stands and platforms are not slip resistant.    a) Manufacturing warehouse:    Employees climbed on mobile ladder stands, which were placed next to chemical mixer tanks, to assist in producing detergents. Liquid chemical ingredients spilled and dried up on the steps and platforms of the ladders, and made the steps and platforms slippery. On or about 01/23/2020.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3856

1910.178 L01 I

Serious Gravity 10 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $5398.00 · Current $4000.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):       a) Storage warehouse and manufacturing warehouse:       The employer did not evaluate, train, test, or certify each powered industrial truck operator to ensure that they are competent to operate a powered industrial truck safely. On or about 01/23/2020.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5398

1910.178 L03

Serious Gravity 10 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(3): Powered industrial truck operators did not receive initial training in all of the topics required under this standard, except in topics which the employer can demonstrate are not applicable to safe operation of the truck in the employer's workplace.  a) Storage warehouse and manufacturing warehouse:    The employer did not provide initial training to forklift operators in all of the topics required under this standard to ensure that they are competent to operate forklift trucks safely. On or about 01/23/2020.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3856.00 · Current $1986.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.        a) Manufacturing warehouse:         Employees used a power strip for high power loads such as a microwave oven, a refrigerator, and an industrial ventilation fan, and it was connected to another extension cord. The power strip was not used in accordance with instructions included in the listing or labeling. On or about 01/23/2020.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3856

1910.305 A02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3856.00 · Current $1986.00 Reduced
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners. Note: Temporary electrical power and lighting installation(s) may only be used as specified by 1910.305(a)(2)(i)(A) through 1910.305(a)(2)(i)(C).       a) Manufacturing warehouse:       Employees used a power strip that was connected to another extension cord, which was routed along the walls to an energized outlet at another part of the warehouse. Temporary wiring was used in a prohibited manner. On or about 01/23/2020.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3856

5(a)(1)

Serious Gravity 10 2 instances 15 exposed
Issued
Abate by
Penalty
Initial $5398.00 · Current $3042.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to hazards of being struck by falling steel storage racks and/or components of the steel storage racks, including any materials stored on the racks:       a) Storage warehouse and manufacturing warehouse:       Bottoms of steel storage rack columns were not anchored to the floor with anchor bolts to support loads and resist forces from potentially being struck by moving equipment. Employees engaged in material handling operations were exposed to being struck and crushed by falling steel storage racks and/or components of the steel storage racks, including any materials stored on the racks. On or about 01/23/2020.    Abatement Note: among other methods one feasible and acceptable method to correct this hazard is to:     Follow ANSI MH16.1:2012, "Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks.", under "1.4.7 Column Base Plates and Anchors", which states: "The bottom of all columns shall be furnished with column base plates, as specified in Section 7.1. All rack columns shall be anchored to the floor with anchor bolts, which shall be designed in accordance with Section 7.3, to resist all applicable forces as described in Section 2.1 or Section 2.2."      b) Storage warehouse and manufacturing warehouse:       The employer did not repair and/or evaluate the damaged portions of the steel storage racks to ensure that the racks have the structural integrity to support loads and resist forces from potentially being struck by moving equipment. Employees engaged in material handling operations were exposed to being struck and crushed by falling steel storage racks and/or components of the steel storage racks, including any materials stored on the racks. On or about 01/23/2020.    Abatement Note: among other methods one feasible and acceptable method to correct this hazard is to:     Follow ANSI MH16.1:2012, "Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks.", under "1.4.9 Rack Damage", which states: "Upon any visible damage, the pertinent portions of the rack shall be immediately isolated by the user until the damaged portion is evaluated by a storage rack design professional. Before allowing the rack to be placed back into service the design professional must certify that the rack system and/or the repaired components have been restored to at least their original design capacity."
Recent events (2)
  • — I (S) $3042
  • — Z (S) $5398

View SUN LABS GROUP LLC's full OSHA safety record →