HENDERSON, TX ·
OSHA Inspection: CASE HILL GROUP INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CASE HILL GROUP INCORPORATED in 3200 COUNTY ROAD 203 NORTH, HENDERSON, TX 75652 (NAICS 321214). OSHA activity number 344579495.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CASE HILL GROUP INCORPORATED
- Site address
- 3200 COUNTY ROAD 203 NORTH
- City
- HENDERSON
- State
- TX
- ZIP
- 75652
- Mailing
- PO BOX 817, HENDERSON, TX 75652
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321214
- Employees
- 78
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.213 A09
- Issued
- Feb 21, 2020
- Penalty
- Initial $6,747 · Current $3,800 Reduced
General-duty citation text
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219(f)(3): On or about January 13, 2020 employees at the site were exposed to caught in hazards when catching lumber near unguarded shafts in the Saw Department in the following instances: 1) The Monet #1 2x4 Saw Machine. 2) The Monet #2 2x4 Saw Machine.
Recent events (2)
- · I (S) $3800
- · Z (S) $6747
1910.303 B01
- Issued
- Feb 21, 2020
- Penalty
- Initial $8,096 · Current $3,800 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: (a) On or about 01/21/2020 employees at the site were exposed to electrical shock hazards while when utilizing a microwave in the break area which was not grounded.
Recent events (2)
- · I (S) $3800
- · Z (S) $8096
More inspections in this industry (NAICS 321214)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344579495.