Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACTION PACKED DEMOLITION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACTION PACKED DEMOLITION in 1000 MAIN AVE, CLIFTON, NJ 07011 (NAICS 238910). OSHA activity number 344587092.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Action Packed Demolition — free Get an email when a new federal OSHA severe-injury report for Action Packed Demolition is published. One employer, no account, unsubscribe in one click.
Site address
1000 MAIN AVE
City
CLIFTON
State
NJ
ZIP
07011
Mailing
19 CLIFF ST, BEACON, NY 12508
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.350 A09

Serious Gravity 5 1 instance 11 exposed
Issued
Jan 31, 2020
Penalty
Initial $2,313 · Current $2,313
29 CFR 1926.350(a)(9): Compressed gas cylinder(s) were not secured in an upright position:  a) Interior of building - North Entrance: Oxygen and acetylene cylinders were not secured for several days, on or about 10/15/19
Recent events (1)
  • — Z (S) $2313

1926.350 A10

Serious Gravity 5 1 instance 11 exposed
Issued
Jan 31, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour.   a) Interior of building - North Entrance: Oxygen and acetylene cylinders were not secured and were stored next to each other without a noncombustible barrier between them for several days, on or about 10/15/19
Recent events (1)
  • — Z (S) $0