OSHA Inspection: SA-FE GLASS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SA-FE GLASS INC. in 86 DELANCEY STREET, NEW YORK, NY 10002 (NAICS 238190). OSHA activity number 344589775.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sa-Fe Glass INC. for free Get an email when a new federal OSHA severe-injury report for Sa-Fe Glass INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SA-FE GLASS INC.
Site address
86 DELANCEY STREET
City
NEW YORK
State
NY
ZIP
10002
Mailing
206 W KENDING ROAD, WILLOW STREET, PA 17584
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
238190
Employees
20
Ownership type
Private (A)

2 citations on file for this inspection.

1926.502 D06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2020
Penalty
Initial $3,856 · Current $3,856
29 CFR 1926.502(d)(6)(i): A snaphook not of the design type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other; (iii) to a Dee-ring to which another snaphook or other connector is attached; (iv) to a horizontal lifeline; or (v) to any object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself:  Location: a) 12th floor exterior wall; set-back area  a) On or about 01/29/2020, an employee was using a lifeline, as a part of his fall protection system, with its snaphook engaged directly onto to lifeline rope.
Recent events (1)
  • · Z (S) $3856

1926.502 D16 III

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 3, 2020
Penalty
Initial $5,398 · Current $5,398
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  Location: a) 12th floor exterior wall; set-back area  a) On or about 01/29/2020, an employee connected his lanyard to the vertical lifeline. The lifeline was too long to stop the employee from free falling less than 6 feet.