BRADLEY, IL —
OSHA Inspection: M. & O. INSULATION COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of M. & O. INSULATION COMPANY in CSL BEHRING 1201 N. KINZIE AVE., BRADLEY, IL 60915 (NAICS 238310). OSHA activity number 344591516.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M. & O. INSULATION COMPANY
- Site address
- CSL BEHRING 1201 N. KINZIE AVE.
- City
- BRADLEY
- State
- IL
- ZIP
- 60915
- Mailing
- 17217 S. ASHLAND AVE., HAZEL CREST, IL 60429
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Apr 3, 2020
- Penalty
- Initial $12,145 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):(a) a. B4 Interstitial Space - On or about January 21, 2020, at the above worksite, employees were exposed to machine hazards associated with moving parts when re-insulating the Niagra cooling unit. The employer failed to contact the host employer to implement energy control application steps as the cooling unit was not shut down or turned off to perform servicing work [per the 1910.147(d)(2) requirements.] As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.
Recent events (2)
- — I (S) $7000
- — Z (S) $12145
More inspections at M. & O. Insulation Company
View M. & O. Insulation Company's full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344591516.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.