Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: LEWIS CUSTOM HOMES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LEWIS CUSTOM HOMES, INC. in LEWISTON AT SENECA, 7687 STATE ROUTE 5, CLINTON, NY 13323 (NAICS 236117). OSHA activity number 344593371.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lewis Custom Homes, INC. for free Get an email when a new federal OSHA severe-injury report for Lewis Custom Homes, INC. is published. One employer, no account, unsubscribe in one click.
Site address
LEWISTON AT SENECA, 7687 STATE ROUTE 5
City
CLINTON
State
NY
ZIP
13323
Mailing
194 CLINTON ROAD #5304, NEW HARTFORD, NY 13413
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236117
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.304 F

Serious Gravity 5 1 instance 1 exposed
Issued
May 6, 2020
Abate by
May 18, 2020
Penalty
Initial $2,892 · Current $2,892
29 CFR 1926.304(f)  Section 4.1.2(b)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator:         29 CFR 1926.304(f)  Section 4.1.2(c)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:         29 CFR 1926.304(f)  Section 5.1.3.3  American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure:          a)Building #2, Unit #1, first floor, on or about 1-30-20:  One employee was ripping vinyl flooring using a table saw that was not equipped with a spreader.     b) Building #2, Unit #1, first floor, on or about 1-30-20:  One employee was ripping vinyl flooring using a table saw that was not equipped with non kick-back fingers or "dogs".     c) Building #2, Unit #1, first floor, on or about 1-30-20:  One employee was ripping vinyl flooring using a table saw that was not equipped with a magnetic switch or anti-restart device.   ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • · I (S) $2892
  • · Z (S) $2892

1926.304 I01

Serious Gravity 5 1 instance 1 exposed
Issued
May 6, 2020
Abate by
May 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut:    a) West side of building, on or about 7-25-19:  Employees were using a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade.  ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.405 G02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
May 1, 2020
Penalty
Initial $2,313 · Current $0 Reduced
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:       a)Building #2, Unit #1, first floor, on or about 1-30-20:  One employee was operating a table saw, equipped with a power cord that exhibited a broken strain relief.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2313

1926.403 B02

Other-than-serious 1 instance 1 exposed
Issued
May 1, 2020
Penalty
Initial $1,735 · Current $0 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:       a) Building #2, Unit #1, first floor, on or about 1-30-20:  One employee was operating various power tools that were plugged into a relocatable power tap (RPT), not being used in accordance with the manufacturers recommendations or as listed and labeled.
Recent events (2)
  • · I (O) $0
  • · Z (S) $1735

1926.1052 C01 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 1, 2020
Abate by
May 11, 2020
Penalty
Initial $2,313 · Current $2,313
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:    a) Building #2, Unit #1, first floor, on or about 1-30-20:  Employees were accessing the second floor using a stairway without a stair rail system on the open side of the stairs, exposing the employees to a fall hazard of up to 52 inches.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • · I (S) $2313
  • · Z (S) $2313

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344593371.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.